Literature DB >> 34208090

Magnetically Guided Localization Using a Guiding-Marker System® and a Handheld Magnetic Probe for Nonpalpable Breast Lesions: A Multicenter Feasibility Study in Japan.

Tomoko Kurita1, Kanae Taruno2, Seigo Nakamura2,3, Hiroyuki Takei1, Katsutoshi Enokido4, Takashi Kuwayama2, Yoko Kanada2, Sadako Akashi-Tanaka2, Misaki Matsuyanagi4, Meishi Hankyo1, Keiko Yanagihara1, Takashi Sakatani5, Kentaro Sakamaki6, Akihiro Kuwahata7,8, Masaki Sekino7, Moriaki Kusakabe9,10.   

Abstract

Accurate pre-operative localization of nonpalpable lesions plays a pivotal role in guiding breast-conserving surgery (BCS). In this multicenter feasibility study, nonpalpable breast lesions were localized using a handheld magnetic probe (TAKUMI) and a magnetic marker (Guiding-Marker System®). The magnetic marker was preoperatively placed within the target lesion under ultrasound or stereo-guidance. Additionally, a dye was injected subcutaneously to indicate the extent of the tumor excision. Surgeons checked for the marker within the lesion using a magnetic probe. The magnetic probe could detect the guiding marker and accurately localize the target lesion intraoperatively. All patients with breast cancer underwent wide excision with a safety margin of ≥5 mm. The presence of the guiding-marker within the resected specimen was the primary outcome and the pathological margin status and re-excision rate were the secondary outcomes. Eighty-seven patients with nonpalpable lesions who underwent BCS, from January to March of 2019 and from January to July of 2020, were recruited. The magnetic marker was detected in all resected specimens. The surgical margin was positive only in 5/82 (6.1%) patients; these patients underwent re-excision. This feasibility study demonstrated that the magnetic guiding localization system is useful for the detection and excision of nonpalpable breast lesions.

Entities:  

Keywords:  breast cancer; magnetic maker; magnetic probe; nonpalpable breast lesion; surgery

Year:  2021        PMID: 34208090     DOI: 10.3390/cancers13122923

Source DB:  PubMed          Journal:  Cancers (Basel)        ISSN: 2072-6694            Impact factor:   6.639


  3 in total

1.  Handheld PET Probe for Pediatric Cancer Surgery.

Authors:  Hannah N Rinehardt; Sadie Longo; Ryan Gilbert; Jennifer N Shoaf; Wilson B Edwards; Gary Kohanbash; Marcus M Malek
Journal:  Cancers (Basel)       Date:  2022-04-29       Impact factor: 6.575

2.  A Propensity Score Matched Analysis of Superparamagnetic Iron Oxide versus Radioisotope Sentinel Node Biopsy in Breast Cancer Patients after Neoadjuvant Chemotherapy.

Authors:  Zuzanna Pelc; Magdalena Skórzewska; Maria Kurylcio; Tomasz Nowikiewicz; Radosław Mlak; Katarzyna Sędłak; Katarzyna Gęca; Karol Rawicz-Pruszyński; Wojciech Zegarski; Wojciech P Polkowski; Andrzej Kurylcio
Journal:  Cancers (Basel)       Date:  2022-01-28       Impact factor: 6.639

3.  Exploratory Study of Superparamagnetic Iron Oxide Dose Optimization in Breast Cancer Sentinel Lymph Node Identification Using a Handheld Magnetic Probe and Iron Quantitation.

Authors:  Kanae Taruno; Akihiko Kuwahata; Masaki Sekino; Takayuki Nakagawa; Tomoko Kurita; Katsutoshi Enokido; Seigo Nakamura; Hiroyuki Takei; Moriaki Kusakabe
Journal:  Cancers (Basel)       Date:  2022-03-10       Impact factor: 6.639

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.