Literature DB >> 34207110

Retention Forces of Monolithic CAD/CAM Crowns Adhesively Cemented to Titanium Base Abutments-Effect of Saliva Contamination Followed by Cleaning of the Titanium Bond Surface.

Felix Burkhardt1, João Pitta1, Vincent Fehmer1, Philippe Mojon1, Irena Sailer1.   

Abstract

The aim of this study was to investigate the effects of saliva contamination and the cleaning of the bond surface of titanium base (ti-base) abutments on the bonding stability and retention force values. The bond surface of the ti-base abutments was treated with airborne-particle abrasion. After contamination, the ti-base abutments underwent different cleaning protocols: water spray (H2O); alcohol (ALC); suspension of zirconium particles (SZP); reapplied airborne-particle abrasion (APA); and a control condition without contamination and cleaning (CTR). All lithium disilicate crowns were bonded to the ti-base abutments using a primer and a self-curing composite. Bonded specimens underwent thermo-mechanical aging. Bond failure analysis and pull-off testing were performed. Bond failure occurred more frequently in groups H2O, ALC, SZP, and APA (p < 0.05). Significant differences in retention force values were only found between CTR and ALC (p < 0.05). Specimens which did not show bond failure after ageing had higher retention force values than the specimens that showed bond failure (p < 0.05). Saliva contamination with cleaning can degrade the bonding properties to titanium. For the retention force values, only the protocol with alcohol after contamination could not restore the values.

Entities:  

Keywords:  CAD-CAM; bonding; implant dentistry; pull-off; retention force; saliva contamination; titanium base abutment

Year:  2021        PMID: 34207110     DOI: 10.3390/ma14123375

Source DB:  PubMed          Journal:  Materials (Basel)        ISSN: 1996-1944            Impact factor:   3.623


  2 in total

Review 1.  Laboratory Fracture Resilience of Hybrid Abutments Used in Oral Rehabilitation: A Systematic Review.

Authors:  Luca Favasuli; Paulo S Mascarenhas; Paulo Mauricio
Journal:  J Funct Biomater       Date:  2022-08-15

2.  Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study.

Authors:  Monika Bjelopavlovic; Michael Weyhrauch; Herbert Scheller; Stefan Wentaschek; Karl Martin Lehmann
Journal:  Materials (Basel)       Date:  2022-10-07       Impact factor: 3.748

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.