Literature DB >> 34200690

Portable, Rapid, and Sensitive Time-Resolved Fluorescence Immunochromatography for On-Site Detection of Dexamethasone in Milk and Pork.

Xiangmei Li1, Xiaomin Chen1, Jinxiao Wu2, Zhiwei Liu1, Jin Wang1, Cuiping Song3, Sijun Zhao3, Hongtao Lei1, Yuanming Sun1.   

Abstract

Dexamethasone (DEX) is widely used because of its anti-inflammatory, anti-endotoxin, anti-shock, and stress-enhancing response activities. It can increase the risk of diabetes and hypertension if it is abused or used improperly. However, there is a lack of sensitive and rapid screening methods for DEX in food. In this study, a time-resolved fluorescent microspheres immunochromatographic assay (TRFM-ICA) integrated with a portable fluorescence reader was developed for the quantitative detection of DEX in milk and pork. The cut-off values of the TRFM-ICA were 0.25 ng/mL and 0.7 µg/kg, respectively. The limits of quantitation (LOQs) were 0.003 ng/mL and 0.062 µg/kg, respectively. The recovery rates were 80.0-106.7%, and 78.6-83.6%, respectively, with the coefficients of variation ranging 6.3-12.5%, and 7.5-10.3%, respectively. A parallel experiment for 20 milk and 10 pork samples with LC-MS/MS was carried out to confirm the performance of the on-site application of the developed TRFM-ICA. The results of the two methods are basically the same; the correlation (R2) was >0.98. The establishment of TRFM-ICA will provide a new sensitive and efficient technical support for the rapid screening of DEX in food.

Entities:  

Keywords:  dexamethasone; immunochromatographic assay; milk; pork; time-resolved fluorescent microspheres

Year:  2021        PMID: 34200690     DOI: 10.3390/foods10061339

Source DB:  PubMed          Journal:  Foods        ISSN: 2304-8158


  3 in total

1.  Preparation of Novel Nanomaterial and Its Application in Food Industry.

Authors:  Hong Wu; Hui Zhang
Journal:  Foods       Date:  2022-05-11

2.  A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection.

Authors:  Yongjian Cheng; Bo Xie; Yifan Liang; Xinmei Liu; Haojie Chen; Jiadong Li; Hongtao Lei; Zhili Xiao
Journal:  Curr Res Food Sci       Date:  2022-08-27

3.  Lateral Flow Immunoassay Based on Time-Resolved Fluorescence Microspheres for Rapid and Quantitative Screening CA199 in Human Serum.

Authors:  Xueshima Jiao; Tao Peng; Zhanwei Liang; Yalin Hu; Bo Meng; Yang Zhao; Jie Xie; Xiaoyun Gong; You Jiang; Xiang Fang; Xiaoping Yu; Xinhua Dai
Journal:  Int J Mol Sci       Date:  2022-09-01       Impact factor: 6.208

  3 in total