| Literature DB >> 34198309 |
Michelle DeVries1,2,3,4,5, Jill Sarbenoff1,2,3,4,5, Nancy Scott1,2,3,4,5, Margaret Wickert1,2,3,4,5, Lisa Marie Hayes1,2,3,4,5.
Abstract
PURPOSE: The purpose of this quality improvement project was to evaluate transparent vascular access dressings and the use of a liquid gum mastic adhesive on improving dressing integrity over peripheral intravenous (PIV) insertion sites without increasing medical adhesive-related skin injuries (MARSIs) such as tears. PARTICIPANTS ANDEntities:
Mesh:
Year: 2021 PMID: 34198309 PMCID: PMC8415728 DOI: 10.1097/WON.0000000000000787
Source DB: PubMed Journal: J Wound Ostomy Continence Nurs ISSN: 1071-5754 Impact factor: 1.970
DMAIC Framework Model
| DMAIC Stage | Project Activities | Responsible Parties | Outcomes | Timeline |
|---|---|---|---|---|
| Define | 1. Review baseline audit data on dressing integrity. | 1. Infection control (IC), vascular access team (VAT), nursing professional development (NPD), materials management (MM), wound ostomy certified nurses (WOCs), and manufacturer's sales representative and clinical educators (MCE). | 1. 55% of PIV dressings were intact. | 1. 1 mo |
| Measure | 1. Intact dressings defined as insertion site not being exposed. | 1. IC, NPD, VAT. | 1. 100% of team agreed on definition. | 1. 1 wk |
| Analyze | 1. Trial of a second new dressing (Centurion Sorbaview Shield) plus gum mastic adhesive. Goal is for 80% of the dressings to be intact. | 1. IC, NPD, VAT, WOCs, MCE. | 1. 93% (n =26/28) of Centurion dressings were intact. | 1. 2 wk of education followed by 2 wk of evaluations. |
| Improve | 1. The cost of the second new dressings was significantly higher than updated 3M dressing. Decision was made to see if results could also be obtained using gum mastic adhesive with updated dressing. | 1. IC, NPD, VAT, WOCs, MM, MCE. | 1. 83% (n = 19/23) of dressings were intact. | 1. 2 wk of education followed by 2 wk of evaluations |
| Control | 1. Decision to go with updated 3M dressing plus the use of gum mastic adhesive: | 1. IC, NPD, VAT, WOCs, MM. | 1. 83% (n =19/23) of dressings were intact. | 1. 2 wk of evaluations |
Abbreviations: DMAIC, define, measure, analyze, improve, and control; IMCU, intermediate care unit; MARSI, medical adhesive-related skin injury; PIV, peripheral intravenous.
Baseline, Preimplementation and Postimplementation Percentages for the 4 Dressing Protocols
| Results | Fully Intact | Insertion Site Exposed |
|---|---|---|
| Baseline: 3 audits conducted over 18 mo (sample sizes varied) | 55% | 15% |
| Original dressing kit: 3M 9525HP Securement Dressing plus education | 57% (76/134) | 15% (20/134) |
| Updated new dressing: 3M 1683 Securement Dressing alone plus education | 9% (1/11) | 27% (3/11) |
| New dressing: Centurion Sorbaview Shield plus Mastisol adhesive plus education | 93% (26/28) | 0% |
| Updated dressing: 3M 1683 Securement Dressing plus adhesive plus education | 83% (19/23) | 0% |
Overall Dressing Integrity of New Standardized Protocol With 3M 1683 Securement Dressing + Mastisol Adhesive + Education Over the First 18 Months Postproject Implementation
| Dressing status on Visual Assessment | 4th Quarter 2017 | 1st Quarter 2018 | 2nd Quarter 2018 | 3rd Quarter 2018 | 4th Quarter 2018 | 1st Quarter 2019 | Total October 2017 Through March 2019 |
|---|---|---|---|---|---|---|---|
| Intact | 6,750 | 8,046 | 4,882 | 2,572 | 4,218 | 2,613 | 29,081 |
| Nonintact | 105 | 66 | 75 | 50 | 190 | 93 | 579 |
| Reinforced/lifted | 82 | 59 | 41 | 25 | 88 | 94 | 389 |
| Total | 6,937 | 8,171 | 4,998 | 2,647 | 4,496 | 2,800 | 30,049 |
| Fully intact without reinforcement or lifted edges, % | 97.30 | 98.47 | 97.68 | 97.17 | 93.82 | 93.32 | 96.78 |