| Literature DB >> 34196752 |
Kotaro Nagatsu1, Hisashi Suzuki2, Masami Fukada2, Taku Ito2,3, Jun Ichinose2,3, Yoshio Honda2,3, Katsuyuki Minegishi2, Tatsuya Higashi4, Ming-Rong Zhang2.
Abstract
PURPOSE: We demonstrate cyclotron production of high-quality 225Ac using an electroplated 226Ra target.Entities:
Keywords: Actinium-225; Alpha emitter; Radium-226; Targeted alpha therapy
Mesh:
Substances:
Year: 2021 PMID: 34196752 PMCID: PMC8712309 DOI: 10.1007/s00259-021-05460-7
Source DB: PubMed Journal: Eur J Nucl Med Mol Imaging ISSN: 1619-7070 Impact factor: 9.236
Fig. 1Decay chains for the 4n, 4n + 1, and 4n + 2 series
Fig. 2226Ra target assembly
Fig. 3Separation diagram for 225Ac from the 226Ra matrix
Production results
| Run | #1 | #2 | #3 |
|---|---|---|---|
| Beam condition (Ep = 15.6 MeV) | 20 µA × 3 h | 20 µA × 5 h | 20 µA × 5 h |
| Ra deposition | |||
| 226Ra, initial electrolyte | 14.5 MBq (391 µCi) | 36.4 MBq (984 µCi) | 38.8 MBq (1.05 mCi) |
| 226Ra, deposited | 13.5 MBq (366 µCi) | 35.4 MBq (956 µCi) | 37.5 MBq (1.01 mCi) |
| Deposition rate (%) | 94 | 97 | 97 |
| Nuclides of interest* in the initially purified sample (kBq, decay corrected to EOB) | |||
| 225Ac (150 keV, 0.6%) | 522 | 2.23 × 103 | 2.43 × 103 |
| 226Ac (230 keV, 26.9%) | 111 | 451 | 488 |
| 224Ac (215 keV, 52.3%) | Not detected | Not detected | Not detected |
| 226Ra (186 keV, 3.64%) | Not detected | Not detected | Not detected |
| 214Pb (352 keV, 35.6%) | Not detected | Not detected | Not detected |
| 214Bi (609 keV, 45.5%) | 5.2 | 13.5 | 33.3 |
| 135La (481 keV, 1.52%) | 84.5 | 333 | 344 |
| 140La (487 keV, 43.9%) | 0.0571 | 0.165 | 0.231 |
| 212Bi (727 keV, 6.58%) | Trace | Trace | Trace |
| 208Tl (2615 keV, 99.8%) | Trace | Trace | Trace |
*Nuclear data presented in parenthesis are used for quantification[15]
Fig. 4Deposition profile of (a) approximately 37 MBq (1 mCi) of 226Ra on the target surface and (b) 5 mg of Ba. Both electrodepositions are performed under the same conditions (100 mA constant DC for 3 h)
Fig. 5Gamma spectrum for various 225Ac samples: (a) 225Ac product (initial separation) after 4 days from the end of bombardment (EOB), (b) 225Ac product (secondary separation) after 20 days from EOB, and (c) commercially available authentic 225Ac (generator-made)
Fig. 6Alpha spectrum for the 225Ac product. Aliquot of 0.37–1.85-kBq 225Ac dried on an Al disk measured without a covering for (a) purified 225Ac product after 19 days from the end of bombardment (EOB) and (b) commercially available authentic 225Ac
Fig. 7Diagram of 226Ra recycling