Literature DB >> 34194653

Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study.

Jai Thilak1, Balu C Babu1, Mohan Thadi1, Vipin Mohan1, T Arun Kumar1, Prajwal P Mane1, Greeshma C Ravindran2.   

Abstract

AIM: The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee arthroplasty(RATKA) and manual total knee arthroplasty(MTKA) to their respective preoperative plan. PATIENTS AND METHODS: This was a prospective observational study conducted in a tertiary care centre between August 2018 and January 2020. 143 consecutive RATKA(105 patients) and 151 consecutive MTKA(111 patients) performed by two experienced arthroplasty surgeons were included. Two independent observers evaluated the accuracy of implant positioning by measuring the radiological parameters according to the Knee-Society-Roentgenographic-Evaluation-System and limb alignment from postoperative weight-bearing scanogram. Outcomes were defined, based on the degree of deviation of measurements from the planned position and alignment, as excellent(0-1.99°), acceptable(2.00-2.99°) and outlier(≥ 3.00°).
RESULTS: There were no systematic differences in the demographic and baseline characteristics between RATKA and MTKA. Statistically significant outcomes were observed favouring robotic group for postoperative mechanical axis (p < .001), coronal inclination of the femoral component (p < 0.001), coronal inclination of tibial component (p < 0.001), and sagittal inclination of tibial component (p < 0.001). There was no significant difference in the sagittal inclination of the femoral component (p = 0.566). The percentage of knees in the 'excellent' group were higher in RATKA compared to MTKA. There was absolutely no outlier in terms of limb alignment in the RATKA group versus 23.8% (p < 0.001) in the MTKA group. All the measurements showed high interobserver and intraobserver reliability.
CONCLUSION: Robotic-arm assisted TKA executed the preoperative plan more accurately with respect to limb alignment and implant positioning compared to manual TKA, even when the surgeons were more experienced in the latter. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s43465-020-00324-y. © Indian Orthopaedics Association 2021.

Entities:  

Keywords:  Accuracy; Arthroplasty; Implant position; Limb alignment; Manual; Osteoarthritis; Radiology; Robotic surgery; Robotic-arm assisted; Total knee arthroplasty

Year:  2021        PMID: 34194653      PMCID: PMC8192671          DOI: 10.1007/s43465-020-00324-y

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  41 in total

1.  Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study.

Authors:  M Sparmann; B Wolke; H Czupalla; D Banzer; A Zink
Journal:  J Bone Joint Surg Br       Date:  2003-08

Review 2.  Shorter survival rate in varus-aligned knees after total knee arthroplasty.

Authors:  Hai-Xiao Liu; Ping Shang; Xiao-Zhou Ying; Yu Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-16       Impact factor: 4.342

Review 3.  Alignment in total knee replacement.

Authors:  J M Sikorski
Journal:  J Bone Joint Surg Br       Date:  2008-09

4.  Contemporary failure aetiologies of the primary, posterior-stabilised total knee arthroplasty.

Authors:  M P Abdel; C K Ledford; A Kobic; M J Taunton; A D Hanssen
Journal:  Bone Joint J       Date:  2017-05       Impact factor: 5.082

5.  Deviation of femoral intramedullary alignment rod influences coronal and sagittal alignment during total knee arthroplasty.

Authors:  Yohei Haruta; Shinya Kawahara; Kanenobu Tsuchimochi; Akihiko Hamasaki; Toshihiko Hara
Journal:  Knee       Date:  2018-05-16       Impact factor: 2.199

Review 6.  Robotics in Arthroplasty: A Comprehensive Review.

Authors:  David J Jacofsky; Mark Allen
Journal:  J Arthroplasty       Date:  2016-05-18       Impact factor: 4.757

7.  The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty.

Authors:  Seyyed Morteza Kazemi; Tooraj Shafaghi; Reza Minaei; Reza Osanloo; Hashem Abrishamkarzadeh; Farshad Safdari
Journal:  Arch Bone Jt Surg       Date:  2017-07

8.  Early patient-reported outcomes versus objective function after total hip and knee arthroplasty: a prospective cohort study.

Authors:  I E Luna; H Kehlet; B Peterson; H R Wede; S J Hoevsgaard; E K Aasvang
Journal:  Bone Joint J       Date:  2017-09       Impact factor: 5.082

9.  Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment.

Authors:  I Kutzner; A Bender; J Dymke; G Duda; P von Roth; G Bergmann
Journal:  Bone Joint J       Date:  2017-06       Impact factor: 5.082

10.  Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study.

Authors:  Nicholas Bardakos; Akin Cil; Brandon Thompson; Greg Stocks
Journal:  J Arthroplasty       Date:  2007-07-26       Impact factor: 4.757

View more
  2 in total

1.  Robotic-arm assisted versus conventional technique for total knee arthroplasty: early results of a prospective single centre study.

Authors:  Chenkai Li; Tao Li; Zian Zhang; Hui Huang; Chun Rong; Wanping Zhu; Haining Zhang
Journal:  Int Orthop       Date:  2022-02-28       Impact factor: 3.479

2.  Accuracies of bone resection, implant position, and limb alignment in robotic-arm-assisted total knee arthroplasty: a prospective single-centre study.

Authors:  Chenkai Li; Zian Zhang; Guanrong Wang; Chun Rong; Wanping Zhu; Xinzhe Lu; Yikai Liu; Haining Zhang
Journal:  J Orthop Surg Res       Date:  2022-01-29       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.