Literature DB >> 34192102

Non-Contact Respiratory Rate Estimation in Real-Time With Modified Joint Unscented Kalman Filter.

Can Uysal1, Altan Onat1,2, Tansu Filik1.   

Abstract

It can be life-saving to monitor the respiratory rate (RR) even for healthy people in real-time. It is reported that the infected people with coronavirus disease 2019 (COVID-19), generally develop mild respiratory symptoms in the early stage. It will be more important to continuously monitor the RR of people in nursing homes and houses with a non-contact method. Conventional, contact-based, methods are not suitable for long-term health monitoring especially in-home care services. The potentials of wireless radio signals for health care applications, such as fall detection, etc., are examined in literature. In this paper, we focus on a device-free real-time RR monitoring system using wireless signals. In our recent study, we proposed a non-contact RR monitoring system with a batch processing (delayed) estimation method. In this paper, for real-time monitoring, we modify the standard joint unscented Kalman filter (JUKF) method for this new and time-critical problem. Due to the nonlinear structure of the RR estimation problem with respect to the measurements, a novel modification is proposed to transform measurement errors into parameter errors by using the hyperbolic tangent function. It is shown in the experiments conducted with the real measurements taken using healthy volunteers that the proposed modified joint unscented Kalman filter (ModJUKF) method achieves the highest accuracy according to the windowing-based methods in the time-varying RR scenario. It is also shown that the ModJUKF not only reduces the computational complexity approximately 8.54% but also improves the accuracy 36.7% with respect to the standard JUKF method. This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/.

Entities:  

Keywords:  Unscented Kalman filter; device-free; health monitoring; joint unscented Kalman filter; radio signals; respiratory rate tracking; vital signs

Year:  2020        PMID: 34192102      PMCID: PMC8043505          DOI: 10.1109/ACCESS.2020.2998117

Source DB:  PubMed          Journal:  IEEE Access        ISSN: 2169-3536            Impact factor:   3.367


  2 in total

1.  Smart deployment of IoT-TelosB service care StreamRobot using software-defined reliability optimisation design.

Authors:  Kennedy Chinedu Okafor; Omowunmi Mary Longe
Journal:  Heliyon       Date:  2022-06-07

2.  Diagnosis of COVID-19 and non-COVID-19 patients by classifying only a single cough sound.

Authors:  Mesut Melek
Journal:  Neural Comput Appl       Date:  2021-07-30       Impact factor: 5.102

  2 in total