Literature DB >> 34191101

[18F]FDG PET/CT imaging disproves renal allograft acute rejection in kidney transplant recipients with acute kidney dysfunction: a validation cohort.

P Lovinfosse1, L Weekers2, H Pottel3, A Bouquegneau2, C Bonvoisin2, C Bovy2,4, S Grosch2,4, R Hustinx1,5, Francois Jouret6,7.   

Abstract

PURPOSE: [18F]FDG PET/CT may predict the absence of acute allograft rejection (AR) in kidney transplant recipients (KTRs) with acute kidney injury (AKI). Still, the proposed threshold of 1.6 of the mean of mean standardized uptake values (mSUVmean) in the renal parenchyma needs validation.
METHODS: We prospectively performed 86 [18F]FDG PET/CT in 79 adult KTRs who underwent per-cause transplant biopsy for suspected AR. Biopsy-proven polyoma BK nephropathies (n = 7) were excluded. PET/CT was performed 192 ± 18 min after administration of 254.4 ± 30.4 MBq of [18F]FDG. The SUVmean was measured in both upper and lower poles of the renal allograft. One-way analysis of variance (ANOVA) and Tukey's studentized range test were sequentially performed. The receiver operating characteristic (ROC) curve was drawn to discriminate "AR" from non-pathological ("normal" + "borderline") conditions.
RESULTS: The median age of the cohort was 55 [43; 63] years, with M/F gender ratio of 47/39. The mean eGFR was 31.9 ± 14.6 ml/min/1.73m2. Biopsies were categorized in 4 groups: "normal" (n = 54), "borderline" (n = 9), "AR" (n = 14), or "others" (n = 2). The median [min; max] mSUVmean reached 1.72 [1.02; 2.07], 1.97 [1.55; 2.11], 2.13 [1.65, 3.12], and 1.84 [1.57; 2.12] in "normal," "borderline," "AR," and "others" groups, respectively. ANOVA demonstrated a significant difference of mSUVmean among groups (F = 13.25, p < 0.0001). The ROC area under the curve was 0.86. Test sensitivity and specificity corresponding to the threshold value of 1.6 were 100% and 30%, respectively.
CONCLUSION: [18F]FDG PET/CT may help noninvasively prevent inessential transplant biopsies in KTR with AKI.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Acute rejection; Banff; Diagnosis; Kidney transplant; [18F]FDG PET/CT

Mesh:

Substances:

Year:  2021        PMID: 34191101     DOI: 10.1007/s00259-021-05467-0

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  2 in total

Review 1.  Non-invasive approaches in the diagnosis of acute rejection in kidney transplant recipients, part II: omics analyses of urine and blood samples.

Authors:  Pauline Erpicum; Oriane Hanssen; Laurent Weekers; Pierre Lovinfosse; Paul Meunier; Luaba Tshibanda; Jean-Marie Krzesinski; Roland Hustinx; François Jouret
Journal:  Clin Kidney J       Date:  2016-09-06

Review 2.  Non-invasive approaches in the diagnosis of acute rejection in kidney transplant recipients. Part I. In vivo imaging methods.

Authors:  Oriane Hanssen; Pauline Erpicum; Pierre Lovinfosse; Paul Meunier; Laurent Weekers; Luaba Tshibanda; Jean-Marie Krzesinski; Roland Hustinx; François Jouret
Journal:  Clin Kidney J       Date:  2016-07-28
  2 in total
  1 in total

1.  Association between diffuse renal uptake of 18F-FDG and acute kidney injury.

Authors:  Eitaro Kidera; Sho Koyasu; Nobuyuki Hayakawa; Takayoshi Ishimori; Yuji Nakamoto
Journal:  Ann Nucl Med       Date:  2022-01-06       Impact factor: 2.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.