| Literature DB >> 34189285 |
Emilien Muggeo-Bertin1, Raphael Moeckli2, Veronique Vallet2, Dominik Berthold3, Sarah Godin1, Jean Bourhis1, Fernanda G Herrera1,4,5.
Abstract
This article describes a ureter-sparing procedure used to treat lymph node metastases with SBRT. We delivered 35 Gy in 5 fractions of 7 Gy to patients with lesions located less than 7 mm from the ureters using a urography CT scan for planification. Two dosimetry plans were created, one using a CT scan urography-based contour and the other using the native phase. PTV coverage were not statistically different but this technique was able to significantly reduce median delivered Dmax to the ureters. These preliminary results demonstrate the feasibility of locating the ureters in a planning CT scan to protect them.Entities:
Keywords: Constraints; Delineation; Stenosis; Stereotactic body radiation therapy; Ureters; Urography CT scan
Year: 2021 PMID: 34189285 PMCID: PMC8215296 DOI: 10.1016/j.tipsro.2021.05.003
Source DB: PubMed Journal: Tech Innov Patient Support Radiat Oncol ISSN: 2405-6324
Fig. 1CT scan images of the abdomen showing the ureters. Images were taken 4 min after injection of iodinated contrast medium. A) Axial view. Distance from ureter to GTV = 4 mm. B) Sagittal view. C) Coronal view. GTV = Gross tumor volume.
Dosimetry analysis for organs at risk.
| Without sparing technique (lack of visualization of the ureter) | With sparing technique (visualizing the ureter with the use of urography CT) | Without sparing technique (lack of visualization of the ureter) | With sparing technique (visualizing the ureter with the use of urography CT) | |
|---|---|---|---|---|
| Ureters | 3.21 (1.99–3.89) | 2.35 (1.71–3.18) | 33.55 (31.41–37.07) | 28.12 (23.26–32.23) |
| Bowel | 0.38 (0.30–1.77) | 0.36 (0.32–1.81) | 17.52 (7.32–35.85) | 17.63 (10.00–35.19) |
| Rectum | 0.19 (0.01–0.46) | 0.21 (0.01–0.44) | 1.02 (0.01–4.58) | 1.14 (0.01–3.74) |
| Bladder | 0.11 (0.01–2.17) | 0.06 (0.01–1.92) | 1.05 (0.01–9.99) | 0.28 (0.01–9.76) |
OARs = Organs at risk
Fig. 2A) Dosimetry of a patient with a metastatic iliac lymph node treated with 35 Gy in 5 fractions of 7 Gy, sagittal view. PTV and GTV are covered by 98% and 100% of the prescribed dose, respectively. Red: 42 Gy isodose line. Orange: 36 Gy isodose line. Yellow: 27 Gy isodose line. Light blue: 13 Gy isodose line. Dark blue: 1 Gy isodose line. B) Bar plot depicts median Dmax (±SEM), dots are individual patient’s values, P-value was calculated using an unpaired t-test with Welch’s correction.PTV = Planning target volume. GTV = Gross tumor volume. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)