Literature DB >> 34187593

What is the diagnostic value of dual-energy computed tomography in patients with clinical diagnosis of gout?

Jung Sun Lee1, Wook Jang Seo2.   

Abstract

OBJECTIVES: To investigate the frequency of monosodium urate (MSU) crystal deposits on dual-energy computed tomography (DECT) in patients with clinical diagnosis of gout and the factors associated MSU crystal positivity.
METHODS: This study was conducted in patients with clinical diagnosis of gout who underwent DECT. Clinical features were compared between patients with positive and those with negative DECT results. A logistic regression analysis was performed to determine the factors associated with MSU crystal positivity on DECT.
RESULTS: A total of 148 patients with clinical diagnosis of gout were included, and MSU crystal deposition on DECT was observed in 64 patients (43.3%). The patients with positive DECT results were more likely to have renal insufficiency, longer disease duration, and higher serum urate level than those with negative. In the multivariable analysis, first gout attack (odds ratio 0.462; 95% confidence interval 0.229-0.931, p = 0.031) was associated with a less likely MSU crystal deposit-positive DECT result. In the subgroup analysis of patients with first attack, serum urate level > 8 mg/dL was associated with DECT positivity.
CONCLUSION: Of the patients with clinical diagnosis of gout, those with renal insufficiency, longer disease duration, and high serum urate level were more likely to be positive of gout on DECT. First gout attack was associated with less likely to be positive for MSU crystal on DECT. Thus, performing DECT scan in the selected patients who had characteristics that highly probability of DECT positivity could increase positive predictive value.

Entities:  

Keywords:  Diagnostic imaging; Dual-energy computed tomography; Gout; Monosodium urate

Mesh:

Year:  2021        PMID: 34187593     DOI: 10.1186/s42358-021-00198-0

Source DB:  PubMed          Journal:  Adv Rheumatol        ISSN: 2523-3106


  22 in total

1.  Identification of crystals in synovial fluid.

Authors:  P Dieppe; A Swan
Journal:  Ann Rheum Dis       Date:  1999-05       Impact factor: 19.103

2.  Diagnostic imaging of gout: comparison of high-resolution US versus conventional X-ray.

Authors:  Thomas Rettenbacher; Sybille Ennemoser; Harald Weirich; Hanno Ulmer; Frank Hartig; Werner Klotz; Manfred Herold
Journal:  Eur Radiol       Date:  2007-11-10       Impact factor: 5.315

Review 3.  Global epidemiology of gout: prevalence, incidence and risk factors.

Authors:  Chang-Fu Kuo; Matthew J Grainge; Weiya Zhang; Michael Doherty
Journal:  Nat Rev Rheumatol       Date:  2015-07-07       Impact factor: 20.543

4.  Dual energy CT: added value in gouty arthritis.

Authors:  J Spermon; C F Van Dijke
Journal:  JBR-BTR       Date:  2013 Jan-Feb

5.  Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study.

Authors:  Tim Bongartz; Katrina N Glazebrook; Steven J Kavros; Naveen S Murthy; Stephen P Merry; Walter B Franz; Clement J Michet; Barath M Akkara Veetil; John M Davis; Thomas G Mason; Kenneth J Warrington; Steven R Ytterberg; Eric L Matteson; Cynthia S Crowson; Shuai Leng; Cynthia H McCollough
Journal:  Ann Rheum Dis       Date:  2014-03-25       Impact factor: 19.103

6.  2015 Gout classification criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative.

Authors:  Tuhina Neogi; Tim L Th A Jansen; Nicola Dalbeth; Jaap Fransen; H Ralph Schumacher; Dianne Berendsen; Melanie Brown; Hyon Choi; N Lawrence Edwards; Hein J E M Janssens; Frédéric Lioté; Raymond P Naden; George Nuki; Alexis Ogdie; Fernando Perez-Ruiz; Kenneth Saag; Jasvinder A Singh; John S Sundy; Anne-Kathrin Tausche; Janitzia Vaquez-Mellado; Steven A Yarows; William J Taylor
Journal:  Ann Rheum Dis       Date:  2015-10       Impact factor: 19.103

7.  Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout.

Authors:  Alan N Baer; Tracie Kurano; Uma J Thakur; Gaurav K Thawait; Matthew K Fuld; Janet W Maynard; Mara McAdams-DeMarco; Elliot K Fishman; John A Carrino
Journal:  BMC Musculoskelet Disord       Date:  2016-02-18       Impact factor: 2.362

Review 8.  Dual-energy CT in gout - A review of current concepts and applications.

Authors:  Hong Chou; Teck Yew Chin; Wilfred C G Peh
Journal:  J Med Radiat Sci       Date:  2017-02-26

9.  Dual-energy computed tomography has limited diagnostic sensitivity for short-term gout.

Authors:  Ertao Jia; Junqing Zhu; Wenhui Huang; Xiaoguang Chen; Juan Li
Journal:  Clin Rheumatol       Date:  2017-08-12       Impact factor: 2.980

10.  Gouty arthritis: decision-making following dual-energy CT scan in clinical practice, a retrospective analysis.

Authors:  M Gamala; S P Linn-Rasker; M Nix; B G F Heggelman; J M van Laar; P C M Pasker-de Jong; J W G Jacobs; R Klaasen
Journal:  Clin Rheumatol       Date:  2018-01-27       Impact factor: 2.980

View more
  2 in total

1.  The role of dual energy computed tomography in the differentiation of acute gout flares and acute calcium pyrophosphate crystal arthritis.

Authors:  Dmitrij Kravchenko; Pantelis Karakostas; Daniel Kuetting; Carsten Meyer; Peter Brossart; Charlotte Behning; Valentin S Schäfer
Journal:  Clin Rheumatol       Date:  2021-10-09       Impact factor: 3.650

2.  The Clinical Utility of Dual-Energy Computed Tomography in the Diagnosis of Gout-A Cross-Sectional Study.

Authors:  Maria Sotniczuk; Anna Nowakowska-Płaza; Jakub Wroński; Małgorzata Wisłowska; Iwona Sudoł-Szopińska
Journal:  J Clin Med       Date:  2022-09-05       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.