Literature DB >> 34183326

Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old.

Yuhao Ye1,2,3, Jing Zhao1,2,3, Lingling Niu1,2,3, Wanru Shi1,2,3, Xiaoying Wang1,2,3, Xingtao Zhou4,2,3.   

Abstract

PURPOSE: To investigate the long-term safety and efficacy of implantable collamer lens (ICL) V4c implantation and changes in the anterior lens density (ALD) in patients with myopia ≥40 years of age.
METHODS: This prospective study included 104 eyes of 52 patients >40 years of age before ICL V4c implantation. Spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity (CDVA), intraocular pressure, endothelial cell density, anterior chamber depth, anterior chamber volume and anterior chamber angle preoperatively, at 1 and 3 months, and at 3 years postoperatively were recorded. Pentacam HR was used to analyse ALD changes at a depth of 0.5, 1.0 and 1.5 mm within a 3 mm diameter range around the pupil's centre.
RESULTS: The overall follow-up was uneventful at 42±7.1 months; the safety index at last follow-up was 1.26±0.35 and the efficacy index was 0.91±0.41. No eye lost the Snellen line of CDVA, 76% of the eyes had an increase in CDVA for ≥1 line and 62% had an SE within ±0.50 dioptre. The increase in ALD at 0.5, 1 and 1.5 mm was 16.52%±10.46%, 16.72%±9.85% and 17.28%±11.93%, respectively. Preoperative, 1-month and 3-month postoperative ALDs showed correlations with SE and age, and ALD at last follow-up was correlated only with age. There was no correlation between ALD and any other parameters.
CONCLUSION: ICL V4c shows long-term safety and efficacy in people ≥40 years of age. ALD increased in such patients, which may be related to age and SE. © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  imaging; lens and zonules; posterior chamber; treatment surgery

Mesh:

Year:  2021        PMID: 34183326     DOI: 10.1136/bjophthalmol-2021-319205

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   5.908


  2 in total

Review 1.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

2.  Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia.

Authors:  Esther López-Artero; Francisco Poyales; Nuria Garzón; Alicia Matamoros; Alba Sáez; Ying Zhou; María García-Montero
Journal:  Int J Environ Res Public Health       Date:  2022-05-31       Impact factor: 4.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.