Abstract

Two methods for rapid detection of adenovirus were tested: (i) 24-well plate centrifugation followed by staining with a monoclonal antibody after incubation for 24 h and 48 h, and (ii) pretreatment of A549 cells used in conventional cell culture and 24-well plate centrifugation with 10(-5)M dexamethasone. Twenty-seven clinical isolates of adenovirus and 12 specimens from which adenovirus had been recovered were included in the analysis. Both isolates and specimens had been frozen at -70 degrees C for up to 6 months. By 24-well plate centrifugation both with and without dexamethasone, 21 (78%) and 27 (100%) isolates were positive for adenovirus at 24 h and 48 h, respectively. Of the specimens, 6 (50%) and 8 (67%) were positive by 24-well plate centrifugation without dexamethasone at 24 h and 48 h, respectively, whereas with dexamethasone 3 (25%) were positive at 24 h and 7 (58%) were positive at 48 h. Overall, combining isolates and specimens, the sensitivity of 24-well plate centrifugation for detection of adenovirus at 24 h was 69% without dexamethasone and 62% with dexamethasone, and at 48 h the sensitivity was 90% without dexamethasone and 87% with dexamethasone. The specificity under all conditions tested was 100%. In conventional tissue culture dexamethasone inhibited recovery of adenovirus. Without dexamethasone, adenovirus was recovered from all 39 samples within 7 days after inoculation; however with dexamethasone pretreatment, the virus was detected in only 31 (79%) of the samples tested in the same period of time.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3417840     DOI: 10.1016/0166-0934(88)90144-9

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  Evaluation of four methods for rapid detection of adenovirus.

Authors:  A Trabelsi; B Pozzetto; A D Mbida; F Grattard; A Ros; O G Gaudin
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1992-06       Impact factor: 3.267

Review 2.  Physical and chemical methods for enhancing rapid detection of viruses and other agents.

Authors:  J H Hughes
Journal:  Clin Microbiol Rev       Date:  1993-04       Impact factor: 26.132

3.  Isolation of seven respiratory viruses in shell vials: a practical and highly sensitive method.

Authors:  M A Olsen; K M Shuck; A R Sambol; S M Flor; J O'Brien; B J Cabrera
Journal:  J Clin Microbiol       Date:  1993-02       Impact factor: 5.948