Abstract

BACKGROUND: In 2006, the Centers for Disease Control and Prevention issued guidelines advocating routine HIV screening for all patients. However, false-positive results are a potential patient care threat for low-risk populations even with accurate screening assays. A reduction in HIV false-positive screening results can potentially be seen by switching from the third-generation to a more sensitive and specific fourth-generation screening assay.
METHODS: We studied the impact on the false-positive screening rate of a change to a fourth-generation assay at a regional US Department of Veteran Affairs Medical Center. HIV screening tests performed by the laboratory from March 1, 2016 to February 28, 2017, prior to implementation of the new assay were compared with fourth-generation HIV screening tests performed from March 1, 2017 to February 28, 2018.
RESULTS: Of 7,516 third-generation HIV screening tests reviewed, 52 were reactive on the screening assay; 24 were true positives, 28 were false positives. The following year 7,802 fourth-generation HIV screening tests were performed and 23 were reactive on the screening assay; 16 were true positives and 7 were false positives. The positive predictive value for the third-generation test was 46% and 70% for the fourth-generation test.
CONCLUSIONS: There were fewer false-positive results with testing with the more specific fourth- vs third-generation assay (0.09% vs 0.37%, respectively), which was statistically significant (P = .002). This reduction in false-positive screening would reduce the laboratory workload and would save an estimated $3,875 yearly and reduce the adverse effects of false-positive screening results for patients.
Copyright © 2021 Frontline Medical Communications Inc., Parsippany, NJ, USA.

Entities:  

Year:  2021        PMID: 34177233      PMCID: PMC8221825          DOI: 10.12788/fp.0125

Source DB:  PubMed          Journal:  Fed Pract        ISSN: 1078-4497


  24 in total

1.  Two "HIV-infected" persons not really infected.

Authors:  Robert W Wood; Carol Dunphy; Keith Okita; Paul Swenson
Journal:  Arch Intern Med       Date:  2003 Aug 11-25

2.  False-positive rate of a "fourth-generation" HIV antigen/antibody combination assay in an area of low HIV prevalence.

Authors:  Sinyoung Kim; Jong-Han Lee; Jun Yong Choi; June Myung Kim; Hyon-Suk Kim
Journal:  Clin Vaccine Immunol       Date:  2010-08-04

3.  A diagnostic blind spot: acute infectious mononucleosis or acute retroviral syndrome.

Authors:  Nitipong Permpalung; Patompong Ungprasert; Daych Chongnarungsin; Amara Okoli; Charles L Hyman
Journal:  Am J Med       Date:  2013-09       Impact factor: 4.965

4.  The End of Written Informed Consent for HIV Testing: Not With a Bang but a Whimper.

Authors:  Ronald Bayer; Morgan Philbin; Robert H Remien
Journal:  Am J Public Health       Date:  2017-06-22       Impact factor: 9.308

5.  Evaluation of an alternative HIV diagnostic algorithm using specimens from seroconversion panels and persons with established HIV infections.

Authors:  Silvina Masciotra; J Steven McDougal; Jane Feldman; Patrick Sprinkle; Laura Wesolowski; S Michele Owen
Journal:  J Clin Virol       Date:  2011-10-05       Impact factor: 3.168

6.  Which anti-HTLV III/LAV assays for screening and confirmatory testing?

Authors:  P P Mortimer; J V Parry; J Y Mortimer
Journal:  Lancet       Date:  1985-10-19       Impact factor: 79.321

Review 7.  The case for earlier treatment of HIV infection.

Authors:  Scott D Holmberg; Frank J Palella; Kenneth A Lichtenstein; Diane V Havlir
Journal:  Clin Infect Dis       Date:  2004-11-09       Impact factor: 9.079

8.  Evaluation of the Bio-Rad Geenius HIV-1/2 test as a confirmatory assay.

Authors:  Isabel Montesinos; Joelle Eykmans; Marie-Luce Delforge
Journal:  J Clin Virol       Date:  2014-05-13       Impact factor: 3.168

9.  When lab tests lie … heterophile antibodies.

Authors:  Adam Morton
Journal:  Aust Fam Physician       Date:  2014-06

10.  Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.

Authors:  Elizabeth O Mitchell; Greg Stewart; Olivier Bajzik; Mathieu Ferret; Christopher Bentsen; M Kathleen Shriver
Journal:  J Clin Virol       Date:  2013-12       Impact factor: 3.168

View more
  1 in total

1.  Case Report: Erroneous Human Immunodeficiency Virus-1 Diagnosis in a Pregnant Woman Using Centers for Disease Control and Prevention Diagnostic Algorithm.

Authors:  Elizabeth Hastie; Lisa Stangl; Karen Deutsch; Jeffrey Yin; Andrew Hull; Stephen A Spector; Jill Blumenthal
Journal:  Open Forum Infect Dis       Date:  2022-08-09       Impact factor: 4.423

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.