Literature DB >> 34172339

Ultrasound versus Computed Tomography Assessment of Focal Lung Aeration in Invasively Ventilated ICU Patients.

Marry R Smit1, Luigi Pisani2, Eva J E de Bock3, Ferdinand van der Heijden4, Frederique Paulus5, Ludo F M Beenen6, Stije J Leopold7, Michaëla A M Huson8, Patricia C Henwood9, Elisabeth D Riviello10, Andrew P Walden11, Arjen M Dondorp2, Marcus J Schultz12, Lieuwe D J Bos5.   

Abstract

It is unknown whether and to what extent the penetration depth of lung ultrasound (LUS) influences the accuracy of LUS findings. The current study evaluated and compared the LUS aeration score and two frequently used B-line scores with focal lung aeration assessed by chest computed tomography (CT) at different levels of depth in invasively ventilated intensive care unit (ICU) patients. In this prospective observational study, patients with a clinical indication for chest CT underwent a 12-region LUS examination shortly before CT scanning. LUS images were compared with corresponding regions on the chest CT scan at different subpleural depths. For each LUS image, the LUS aeration score was calculated. LUS images with B-lines were scored as the number of separately spaced B-lines (B-line count score) and the percentage of the screen covered by B-lines divided by 10 (B-line percentage score). The fixed-effect correlation coefficient (β) was presented per 100 Hounsfield units. A total of 40 patients were included, and 372 regions were analyzed. The best association between the LUS aeration score and CT was found at a subpleural depth of 5 cm for all LUS patterns (β = 0.30, p < 0.001), 1 cm for A- and B1-patterns (β = 0.10, p < 0.001), 6 cm for B1- and B2-patterns (β = 0.11, p < 0.001) and 4 cm for B2- and C-patterns (β = 0.07, p = 0.001). The B-line percentage score was associated with CT (β = 0.46, p = 0.001), while the B-line count score was not (β = 0.07, p = 0.305). In conclusion, the subpleural penetration depth of ultrasound increased with decreased aeration reflected by the LUS pattern. The LUS aeration score and the B-line percentage score accurately reflect lung aeration in ICU patients, but should be interpreted while accounting for the subpleural penetration depth of ultrasound.
Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Computed tomography; Critical care; Lung aeration; Lung ultrasound; Mechanical ventilation

Mesh:

Year:  2021        PMID: 34172339     DOI: 10.1016/j.ultrasmedbio.2021.05.019

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Thromboelastography Profile Is Associated with Lung Aeration Assessed by Point-of-Care Ultrasound in COVID-19 Critically Ill Patients: An Observational Retrospective Study.

Authors:  Daniele Guerino Biasucci; Maria Grazia Bocci; Danilo Buonsenso; Luca Pisapia; Ludovica Maria Consalvo; Joel Vargas; Domenico Luca Grieco; Gennaro De Pascale; Massimo Antonelli
Journal:  Healthcare (Basel)       Date:  2022-06-22

2.  Improvement of an interobserver agreement of ARDS diagnosis by adding additional imaging and a confidence scale.

Authors:  Laura A Hagens; Fleur L I M Van der Ven; Nanon F L Heijnen; Marry R Smit; Hester A Gietema; Suzanne C Gerretsen; Marcus J Schultz; Dennis C J J Bergmans; Ronny M Schnabel; Lieuwe D J Bos
Journal:  Front Med (Lausanne)       Date:  2022-08-31

3.  Reliability and clinical correlations of semi-quantitative lung ultrasound on BLUE points in COVID-19 mechanically ventilated patients: The 'BLUE-LUSS'-A feasibility clinical study.

Authors:  Gábor Orosz; Pál Gyombolai; József T Tóth; Marcell Szabó
Journal:  PLoS One       Date:  2022-10-14       Impact factor: 3.752

Review 4.  Personalized mechanical ventilation in acute respiratory distress syndrome.

Authors:  Paolo Pelosi; Lorenzo Ball; Carmen S V Barbas; Rinaldo Bellomo; Karen E A Burns; Sharon Einav; Luciano Gattinoni; John G Laffey; John J Marini; Sheila N Myatra; Marcus J Schultz; Jean Louis Teboul; Patricia R M Rocco
Journal:  Crit Care       Date:  2021-07-16       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.