Literature DB >> 34166873

Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments.

Sevda Atalay1, Gülce Çakmak2, Manrique Fonseca3, Martin Schimmel4, Burak Yilmaz5.   

Abstract

PURPOSE: To evaluate the effect of thermocycling on the water contact angle (WCA), surface roughness (SR), and microhardness (MH) of different CAD-CAM PMMA denture base materials after different surface treatments (conventional laboratory polishing, polishing kit, or surface sealant).
MATERIALS AND METHODS: Disk-shaped specimens (10 × 2 mm) of 3 different CAD-CAM PMMAs, AvaDent (AV); Merz M-PM (M-PM); Polident (Poli), and a conventional heat-polymerized PMMA (Vynacron) (CV) (n=21) were divided into 3 different surface treatment groups (n=7): conventional laboratory polishing (CLP), polishing with acrylic resin polisher kit (PK), and a surface sealant (Palaseal) (SSC). Stereomicroscopic images were taken both before and after thermocycling. WCA, SR, and MH of all specimens were measured before and after thermocycling and compared by using a 2-way ANOVA (α=0.05).
RESULTS: After thermocycling, WCA significantly increased for CLP- or PK -applied (P<.001) specimens of all materials and SSC-applied M-PM (P=.002), SR significantly increased for CLP-applied M-PM (P=.027) and PK-applied Poli (P=.041), and MH significantly decreased for CLP- or PK-applied AV (P = .001, P < .001, respectively), CV (P=.033, P=.023, respectively), and M-PM (P=.003, P=.001, respectively), SSC-applied M-PM (P<.001), and CLP-applied Poli (P<.001). Stereomicroscopic images revealed rougher surfaces for PK-applied specimens.
CONCLUSIONS: After thermocycling, surface treatment had a significant effect on water contact angle and surface roughness. CLP or PK application resulted in hydrophobic surfaces compared with before thermocycling. CLP or SSC application on CAD-CAM PMMAs resulted in smoother surfaces. Thermocycling lowered the microhardness of all PMMAs, and the decrease was significant in CLP- or PK-applied PMMAs, except for PK-applied Poli.
Copyright © 2021 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  CAD-CAM materials; Microhardness; PMMA dentures; Surface roughness; Thermocycling; Water contact angle

Year:  2021        PMID: 34166873     DOI: 10.1016/j.jmbbm.2021.104646

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  In vitro study of surface properties and microbial adhesion of various dental polymers fabricated by different manufacturing techniques after thermocycling.

Authors:  Xia Wei; Linjuan Gao; Kun Wu; Yu Pan; Lei Jiang; Honglei Lin; Yinghui Wang; Hui Cheng
Journal:  Clin Oral Investig       Date:  2022-08-17       Impact factor: 3.606

2.  Surface Characteristics and Color Stability of Dental PEEK Related to Water Saturation and Thermal Cycling.

Authors:  Liliana Porojan; Flavia Roxana Toma; Mihaela Ionela Bîrdeanu; Roxana Diana Vasiliu; Ion-Dragoș Uțu; Anamaria Matichescu
Journal:  Polymers (Basel)       Date:  2022-05-25       Impact factor: 4.967

3.  Effect of Candida albicans Suspension on the Mechanical Properties of Denture Base Acrylic Resin.

Authors:  Grzegorz Chladek; Michał Nowak; Wojciech Pakieła; Anna Mertas
Journal:  Materials (Basel)       Date:  2022-05-27       Impact factor: 3.748

4.  Surface Characterisation of Dental Resin Composites Related to Conditioning and Finishing.

Authors:  Liliana Porojan; Roxana Diana Vasiliu; Mihaela Ionela Bîrdeanu; Sorin Daniel Porojan
Journal:  Polymers (Basel)       Date:  2021-12-03       Impact factor: 4.329

5.  Changes in the Surface Texture of Thermoplastic (Monomer-Free) Dental Materials Due to Some Minor Alterations in the Laboratory Protocol-Preliminary Study.

Authors:  Bozhana Chuchulska; Ilian Hristov; Boyan Dochev; Raycho Raychev
Journal:  Materials (Basel)       Date:  2022-09-24       Impact factor: 3.748

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.