Literature DB >> 34165296

Rational Design of Electrochemiluminescent Devices.

Xiangui Ma1,2, Wenyue Gao3, Fangxin Du1,2, Fan Yuan1,2, Jing Yu4, Yiran Guan1,2, Neso Sojic1,4, Guobao Xu1,2.   

Abstract

ConspectusElectrochemiluminescence (ECL) is a light-emitting process which combines the intriguing merits of both electrochemical and chemiluminescent methods. It is an extensively used method especially in clinical analysis and biological research due to its high sensitivity, wide dynamic range, and good reliability. ECL devices are critical for the development and applications of ECL. Much effort has been expended to improve the sensitivity, portability, affordability, and throughput of new ECL devices, which allow ECL to adapt broad usage scenarios.In this Account, we summarize our efforts on the recent development of ECL devices including new electrodes, ECL devices based on a wireless power transfer (WPT) technique, and novel bipolar electrochemistry. As the essential components in the ECL devices, electrodes play an important role in ECL detection. We have significantly improved the sensitivity of luminol ECL detection of H2O2 by using a stainless steel electrode. By using semiconductor materials (e.g., silicon and BiVO4), we have exploited photoinduced ECL to generate intense emission at much lower potentials upon illumination. For convenience, portability, and disposability, ECL devices based on cheap WPT devices have been designed. A small diode has been employed to rectify alternating current into direct current to dramatically enhance ECL intensity, enabling sensitive ECL detection using a smart phone as a detector. Finally, we have developed several ECL devices based on bipolar electrochemistry in view of the convenience of multiplex ECL sensing using a bipolar electrode (BPE). On the basis of the wireless feature of BPE, we have employed movable BPEs (e.g., BPE swimmers and magnetic rotating BPE) for deep exploration of the motional and ECL properties of dynamic BPE systems. To make full use of the ECL solution, we have dispersed numerous micro-/nano-BPEs in solution to produce intense 3D ECL in the entire solution, instead of 2D ECL in conventional ECL devices. In addition, the interference of ECL noise from driving electrodes was minimized by introducing the stainless steel with a passivation layer as the driving electrode. To eliminate the need for the fabrication of electrode arrays and the interference from the driving electrode and to decrease the applied voltage, we develop a new-type BPE device consisting of a single-electrode electrochemical system (SEES) based on a resistance-induced potential difference. The SEES is fabricated easily by attaching a multiperforated plate to a single film electrode. It enables the simultaneous detection of many samples and analytes using only a single film electrode (e.g., screen-printed electrode) instead of electrode arrays. It is of great potential in clinical analysis especially for multiple-biomarker detection, drug screening, and biological studies. Looking forward, we believe that more ECL devices and related ECL materials and detection methods will be developed for a wide range of applications, such as in vitro diagnosis, point-of-care testing, high-throughput analysis, drug screening, biological study, and mechanism investigation.

Entities:  

Year:  2021        PMID: 34165296     DOI: 10.1021/acs.accounts.1c00230

Source DB:  PubMed          Journal:  Acc Chem Res        ISSN: 0001-4842            Impact factor:   22.384


  3 in total

1.  A Guide Inside Electrochemiluminescent Microscopy Mechanisms for Analytical Performance Improvement.

Authors:  Sara Rebeccani; Alessandra Zanut; Claudio Ignazio Santo; Giovanni Valenti; Francesco Paolucci
Journal:  Anal Chem       Date:  2021-12-15       Impact factor: 6.986

Review 2.  Electrochemiluminescence with semiconductor (nano)materials.

Authors:  Yiran Zhao; Laurent Bouffier; Guobao Xu; Gabriel Loget; Neso Sojic
Journal:  Chem Sci       Date:  2022-01-28       Impact factor: 9.825

3.  Electrogenerated chemiluminescence of a Ru(bpy)3 2+/arginine system: a specific and sensitive detection of acetaminophen.

Authors:  Yi Xiao; Guofang Wang; Haomin Yi; Suhua Chen; Qinyu Wu; Siyi Zhang; Kexin Deng; Simeng Zhang; Zi-Qi Shi; Xiaoping Yang
Journal:  RSC Adv       Date:  2022-01-24       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.