Literature DB >> 34159480

Radiation exposure in fluoroscopy-guided anterior total hip arthroplasty: a systematic review.

Nayeem Baksh1, Lulu Wei1, Elver S Ho1, Jack J Zhou1, Nicholas D Stekas1, Ahmed M Eldib1, Qais Naziri2.   

Abstract

PURPOSE: To investigate the average fluoroscopy time, as well as the patient and surgical staff average radiation exposure in the context of intraoperative fluoroscopy use during anterior total hip arthroplasty (THA).
METHODS: PubMed, Cochrane, Embase, Web of Science and Scopus were systematically searched for studies pertaining to intraoperative anterior THA fluoroscopy (PROSPERO ID 258049). The comprehensive literary search was conducted using "THA," "fluoroscopy" and "radiation exposure" as the search criteria, which resulted in 187 total papers. Of these 187 papers, 11 studies were included in this systematic review as they involved anterior THA and specifically contained data regarding radiation exposure dose and/or time.
RESULTS: Eleven studies were included, enrolling 1839 patients. The average fluoroscopy time was 21.4 (95% confidence interval [CI] 16.6-26.1) seconds, whereas the average patient radiation dose was 1.8 × 10-3 (95% CI 7.4 × 10-4-2.9 × 10-3) Gy.
CONCLUSIONS: Although several studies fail to report fluoroscopy time and radiation dose in THA patients, fluoroscopy-guided THA has emerged as a safe procedure. Additional studies may analyze if radiation exposure during the surgeon's THA learning curve is significantly higher, as well as what protocols may potentially reduce radiation exposure even further.
© 2021. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.

Entities:  

Keywords:  Intraoperative fluoroscopy; Radiation exposure; Total hip arthroplasty; Total hip replacement

Mesh:

Year:  2021        PMID: 34159480     DOI: 10.1007/s00590-021-03060-7

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  4 in total

1.  Surgical approaches in total hip arthroplasty: a review of the mini-incision and MIS literature.

Authors:  Brett R Levine; Gregg R Klein; Paul E Di Cesare
Journal:  Bull NYU Hosp Jt Dis       Date:  2007

2.  Clinical Results of Direct Anterior Approach THA with Minimal Fluoroscopic Exposure Optimization Techniques.

Authors:  Sergio M Navarro; Christopher Frey; Terri Blackwell; Sarah B Voges; H Del Schutte
Journal:  Surg Technol Int       Date:  2018-11-11

Review 3.  Total hip arthroplasty: areview of advances, advantages and limitations.

Authors:  Xin-Wei Liu; Ying Zi; Liang-Bi Xiang; Yu Wang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 4.  Direct Anterior Total Hip Arthroplasty.

Authors:  Gregory R Galakatos
Journal:  Mo Med       Date:  2018 Nov-Dec
  4 in total
  1 in total

1.  Use of a novel imageless navigation system reduced fluoroscopy exposure and improved acetabular positioning in anterior approach total hip arthroplasty: a case-control study.

Authors:  Christian B Ong; Yu-Fen Chiu; Ajay Premkumar; Alejandro Gonzalez Della Valle
Journal:  Arch Orthop Trauma Surg       Date:  2022-07-01       Impact factor: 3.067

  1 in total