Evolving perspectives on mechanical circulatory support biocompatibility and interfaces.

Marvin J Slepian1,2, Joseph Italiano3, Danny Bluestein2, Jawaad Sheriff2, Yana Roka-Moiia1.   

Abstract

Entities:  

Year:  2021        PMID: 34159123      PMCID: PMC8185380          DOI: 10.21037/acs-2020-cfmcs-247

Source DB:  PubMed          Journal:  Ann Cardiothorac Surg        ISSN: 2225-319X


× No keyword cloud information.
  9 in total

1.  Platelet Activation via Shear Stress Exposure Induces a Differing Pattern of Biomarkers of Activation versus Biochemical Agonists.

Authors:  Yana Roka-Moiia; Ryan Walk; Daniel E Palomares; Kaitlyn R Ammann; Annalisa Dimasi; Joseph E Italiano; Jawaad Sheriff; Danny Bluestein; Marvin J Slepian
Journal:  Thromb Haemost       Date:  2020-05-05       Impact factor: 5.249

2.  Effect of aspirin dose on hemocompatibility-related outcomes with a magnetically levitated left ventricular assist device: An analysis from the MOMENTUM 3 study.

Authors:  Omar Saeed; Paolo C Colombo; Mandeep R Mehra; Nir Uriel; Daniel J Goldstein; Joseph Cleveland; Jean M Connors; Samer S Najjar; Nahush A Mokadam; Aditya Bansal; Daniel L Crandall; Poornima Sood; Ulrich P Jorde
Journal:  J Heart Lung Transplant       Date:  2020-03-20       Impact factor: 10.247

3.  Shear-mediated platelet activation in the free flow: Perspectives on the emerging spectrum of cell mechanobiological mechanisms mediating cardiovascular implant thrombosis.

Authors:  Marvin J Slepian; Jawaad Sheriff; Marcus Hutchinson; Phat Tran; Naing Bajaj; Joe G N Garcia; S Scott Saavedra; Danny Bluestein
Journal:  J Biomech       Date:  2016-11-10       Impact factor: 2.712

4.  Platelet activation is a preoperative risk factor for the development of thromboembolic complications in patients with continuous-flow left ventricular assist device.

Authors:  Filippo Consolo; Giulia Sferrazza; Giulia Motolone; Rachele Contri; Lorenzo Valerio; Rosalba Lembo; Loris Pozzi; Patrizia Della Valle; Michele De Bonis; Alberto Zangrillo; Gianfranco B Fiore; Alberto Redaelli; Marvin J Slepian; Federico Pappalardo
Journal:  Eur J Heart Fail       Date:  2017-12-28       Impact factor: 15.534

5.  Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk.

Authors:  Venkat Keshav Chivukula; Jennifer A Beckman; Anthony R Prisco; Todd Dardas; Shin Lin; Jason W Smith; Nahush A Mokadam; Alberto Aliseda; Claudius Mahr
Journal:  Circ Heart Fail       Date:  2018-04       Impact factor: 8.790

6.  Clinical and In Vitro Evidence That Left Ventricular Assist Device-Induced von Willebrand Factor Degradation Alters Angiogenesis.

Authors:  Carlo R Bartoli; David M Zhang; Samson Hennessy-Strahs; Jooeun Kang; David J Restle; Christian Bermudez; Pavan Atluri; Michael A Acker
Journal:  Circ Heart Fail       Date:  2018-09       Impact factor: 8.790

7.  Aspirin has limited ability to modulate shear-mediated platelet activation associated with elevated shear stress of ventricular assist devices.

Authors:  Lorenzo Valerio; Phat L Tran; Jawaad Sheriff; William Brengle; Ram Ghosh; Wei-Che Chiu; Alberto Redaelli; Gianfranco B Fiore; Federico Pappalardo; Danny Bluestein; Marvin J Slepian
Journal:  Thromb Res       Date:  2016-02-01       Impact factor: 3.944

8.  Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance.

Authors:  Gaurav Girdhar; Michalis Xenos; Yared Alemu; Wei-Che Chiu; Bryan E Lynch; Jolyon Jesty; Shmuel Einav; Marvin J Slepian; Danny Bluestein
Journal:  PLoS One       Date:  2012-03-02       Impact factor: 3.240

9.  Device Thrombogenicity Emulation: An In Silico Predictor of In Vitro and In Vivo Ventricular Assist Device Thrombogenicity.

Authors:  Wei Che Chiu; Phat L Tran; Zain Khalpey; Eric Lee; Yi-Ren Woo; Marvin J Slepian; Danny Bluestein
Journal:  Sci Rep       Date:  2019-02-27       Impact factor: 4.379