On-surface autosampling for liquid chromatography-mass spectrometry.

Annabel Mehl1, Wolfgang Schwack1, Gertrud E Morlock2.   

Abstract

An on-surface multi-purpose autosampler was built for liquid chromatography-mass spectrometry (LC-MS) based on the autoTLC-MS interface, taking advantage of open-source hard- and software developments as well as 3D printing. Termed autoTLC-LC-MS system, it is introduced for orthogonal hyphenation of normal phase high-performance thin-layer chromatography with reversed phase high-performance LC (HPLC) and high-resolution MS (HRMS). For verification of its functionality, a multi-class antibiotic mixture was applied as a calibration band pattern on an adsorbent layer and detected by the Bacillus subtilis bioassay. This effect-image was uploaded as a template in the updated TLC-MS_manager software. The clicked-on antibiotic zones were sequentially eluted without intervention from the planar counterpart (without bioassay) via a monolithic HPLC column into the HRMS system. For elution of antibiotics of 7 structural classes at 5 different calibration levels, the new on-surface autosampler achieved intra-day precisions of 2.1-14.1%, while inter-day precisions ranged 2.5-16.1% (all n = 3). The new hyphenation offers potential for planar sample clean-up prior to HPLC, concentration of liquid samples, increase of peak capacity and proof of peak purity or isomers. The integrated autoTLC-LC-MS system enabled high sample throughput, efficiency and reproducibility for the first time through fully automated TLC-LC-MS sequence operation. Its contact-closure signal functionality, versatile 3D printed planar sample holder and open-source software made it readily adjustable for new analytical tasks. Undoubtedly, any planar material can be investigated for leachables, such as textiles, foils, papers and other packagings, as well as planar biological samples for ingredients.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Orbitrap high-resolution mass spectrometry; Orthogonal hyphenation; Planar chromatography; autoTLC–LC–MS

Year:  2021        PMID: 34153734     DOI: 10.1016/j.chroma.2021.462334

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Build, Share and Remix: 3D Printing for Speeding Up the Innovation Cycles in Ambient Ionisation Mass Spectrometry (AIMS).

Authors:  Nancy Shyrley García-Rojas; Héctor Guillén-Alonso; Sandra Martínez-Jarquín; Abigail Moreno-Pedraza; Leonardo D Soto-Rodríguez; Robert Winkler
Journal:  Metabolites       Date:  2022-02-17

2.  Effect-Directed Profiling of Monofloral Honeys from Ethiopia by High-Performance Thin-Layer Chromatography and High-Resolution Mass Spectrometry.

Authors:  Gertrud E Morlock; Abera Belay; Julia Heil; Annabel Mehl; Hannelore Borck
Journal:  Molecules       Date:  2022-05-31       Impact factor: 4.927

3.  Evidence that Indo-Pacific bottlenose dolphins self-medicate with invertebrates in coral reefs.

Authors:  Gertrud E Morlock; Angela Ziltener; Sascha Geyer; Jennifer Tersteegen; Annabel Mehl; Tamara Schreiner; Tamer Kamel; Franz Brümmer
Journal:  iScience       Date:  2022-05-19