Literature DB >> 3414498

Accurate assessment of aortic stenosis severity by Doppler echocardiography independent of aortic jet velocity.

W A Zoghbi1, A Galan, M A Quinones.   

Abstract

The present investigation was designed to derive an accurate pulsed Doppler method of assessing aortic stenosis severity that does not rely on measurement of aortic jet velocity. Left ventricular ET and SV were determined from pulsed Doppler recordings of flow velocity at the aortic anulus in 44 mostly normotensive patients with aortic stenosis. Aortic valve area at catheterization ranged between 0.3 and 2.13 cm2. A predicted ET was derived from Doppler-determined SV with the use of a regression equation previously described by Harley et al. A significant inverse quadratic relation was observed between the ET difference (delta ET), defined as measured ET minus predicted ET, and valve area at catheterization (r = -0.87; valve area = 1.4 - 15 delta ET + 60 delta ET2; SEE = 0.23 cm2). An ET difference of greater than or equal to 0.060 second was 88% sensitive, 89% specific, and 89% accurate for detecting critical aortic stenosis. Thus the ET difference, derived from measurements of SV and ET by pulsed Doppler, is a sensitive index for detection of critical aortic stenosis that is independent of determination of aortic jet velocity. This index should complement the Doppler evaluation of aortic stenosis, especially in cases where interrogation of the stenotic jet with continuous wave Doppler is inadequate.

Entities:  

Mesh:

Year:  1988        PMID: 3414498     DOI: 10.1016/0002-8703(88)90348-1

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  5 in total

Review 1.  Low "gradient", low flow aortic stenosis.

Authors:  John Chambers
Journal:  Heart       Date:  2006-04       Impact factor: 5.994

Review 2.  Problems in the diagnosis and investigation of aortic stenosis.

Authors:  A Bishop; P Wilkinson
Journal:  Postgrad Med J       Date:  1991-12       Impact factor: 2.401

Review 3.  Challenges in Aortic Valve Stenosis: Low-Flow States Diagnosis, Management, and a Review of the Current Literature.

Authors:  Matthew W Sherwood; Todd L Kiefer
Journal:  Curr Cardiol Rep       Date:  2017-10-30       Impact factor: 2.931

4.  Low Gradient, Low Ejection Fraction Aortic Stenosis.

Authors:  John Chambers
Journal:  Curr Treat Options Cardiovasc Med       Date:  2003-12

5.  Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.

Authors:  J L Fischer; T Haberer; D Dickson; L Henselmann
Journal:  Br Heart J       Date:  1995-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.