| Literature DB >> 34140819 |
Masresha Mengistu1, Fisseha Admassu1, Teshager Wondale1, Asamere Tsegaw1.
Abstract
PURPOSE: According to World Health Organization (WHO), cataract is the leading cause of blindness and visual impairment throughout the world. Post-operative refractive error is one of the commonest reasons for poor visual outcome after cataract surgery especially in developing countries where the standard modern biometry equipments are not available. The objective of this study was to assess the refractive outcome of cataract surgery done at University of Gondar (UoG) Tertiary Eye Care and Training Center, North West Ethiopia.Entities:
Keywords: Ethiopia; Gondar; cataract surgery; outcome
Year: 2021 PMID: 34140819 PMCID: PMC8203275 DOI: 10.2147/PROM.S308816
Source DB: PubMed Journal: Patient Relat Outcome Meas ISSN: 1179-271X
Socio-Demographic Characteristics of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variables | Frequency/Percentage | |
|---|---|---|
| Age (years) | <20 | 3 (4.5%) |
| 21–30 | 0 | |
| 31–40 | 0 | |
| 41–50 | 6 (9.1%) | |
| 51–60 | 15 (22.7%) | |
| 61–70 | 23 (34.8%) | |
| 71–80 | 16 (24.2%) | |
| >80 | 3 (4.5% | |
| Sex | Female | 29 (43.9%) |
| Male | 37 (56.1%) | |
| Residence | Urban | 20 (30.3%) |
| Rural | 46 (69.7%) | |
| Religion | Christian | 61 (92.4%) |
| Muslim | 5 (7.6%) | |
| Occupation | Government employee | 13 (19.7%) |
| Farmer | 20 (30.3%) | |
| Merchant | 8 (12.1%) | |
| Others | 25 (37.9%) | |
Pre-Operative UCVA of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variables | Frequency/Percentage | |||
|---|---|---|---|---|
| OD | OS | OD/OS | ||
| Light perception | 34 (75.6%) | 37 (82.2%) | 71 (79%) | |
| Counts finger (CF) at 1meter distance | 7 (15.6%) | 4 (8.9%) | 11 (12.2%) | |
| Counts finger (CF) at 2meters distance | 4 (8.9%) | 2 (4.4%) | 6 (6.6%) | |
| Counts finger (CF) at 3meters distance | 1 (2.2%) | 1 (1.1%) | ||
| Counts finger (CF) at 4meters distance | 1 (2.2%) | 1 (1.1%) | ||
| Total | 45 | 45 | 90 | |
Pre-Operative Biometric Profile in Millimeter and Diopter of Eyes of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variables | Number of Eyes | Minimum | Maximum | Mean | Standard Deviation | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| OD | OS | OD | OS | OD | OS | OD | OS | OD | OS | |
| A1 (in millimeter) | 45 | 45 | 6.99 | 7.12 | 8.52 | 8.28 | 7.67 | 7.62 | 0.35 | 0.29 |
| A2 (in millimeter) | 45 | 45 | 6.89 | 6.91 | 8.78 | 8.42 | 7.55 | 7.55 | 0.32 | 0.30 |
| AL (in millimeter) | 45 | 45 | 20.99 | 21.41 | 28.96 | 26.42 | 23.18 | 23.10 | 1.26 | 1.05 |
| IOL calculated (diopter) | 45 | 45 | 2 | 5.5 | 24 | 26.50 | 20.21 | 20.65 | 4.16 | 4.00 |
| IOL inserted (diopter) | 45 | 45 | 10.5 | 10 | 24 | 26.50 | 20.88 | 20.45 | 2.72 | 3.65 |
| Difference IOL Implanted and IOL calculated (diopter) | 45 | 45 | −1.00 | −3.00 | 8.50 | 4.50 | 0.100 | 0.18 | 0.38 | 1.03 |
Postoperative Visual Acuity of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variable | Frequency/Percentage | |||
|---|---|---|---|---|
| OD | OS | OD/OS | ||
| Post-operative UCVA | Good | 32 (71.1%) | 28 (62.2%) | 60 (66.7%) |
| Borderline | 8 (17.8%) | 11 (24.4%) | 19 (21%) | |
| Poor | 5 (11.1%) | 6 (13.4%) | 11 (12.3%) | |
| Total | 45 (100) | 45 (100) | 90 (100) | |
| Post-operative BCVA | Good | 38 (84.4%) | 36 (80%) | 74 (82.2%) |
| Borderline | 4 (8.9%) | 5 (11.1%) | 9 (10%) | |
| Poor | 3 (6.7%) | 4 (8.9%) | 7 (7.8%) | |
| Total | 45 (100%) | 45 (100%) | 90 (100%) | |
Post-Operative Refractive Outcome of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variables | Frequency/Percentage | ||
|---|---|---|---|
| Spherical Equivalent (SE) in Diopter | OD | OS | OD/OS |
| <-1 | 12 (26.7%) | 14 (31.1%) | 26 (28.9%) |
| −1 to +1 | 30 (66.7%) | 28 (62.3%) | 58 (64.4%) |
| >+1 | 3 (6.7%) | 3 (6.7%) | 6 (6.7%) |
Comparison of Post-Operative Refraction SE Between the Right and Left Eyes of Patients Operated for Cataract with MSICS Technique at University of Gondar Tertiary Eye Care and Training Center, NW Ethiopia (n = 90).
| Variables | Number | Minimum (in D) | Maximum (D) | Mean (D) | Standard Deviation (D) |
|---|---|---|---|---|---|
| SE in the right eye | 45 | −4.00 | 4.00 | −0.73 | 1.45 |
| SE in the left eye | 45 | −4.25 | 6.25 | −0.93 | 1.70 |