Literature DB >> 34140226

A Comparison of Computed Tomography Angiography and Colour Duplex Ultrasound Surveillance Post Infrarenal Endovascular Aortic Aneurysm Repair: Financial Implications and Impact of Different International Surveillance Guidelines.

Luke Smith1, Nicholas Thomas2, Andrew Arnold2, Rachel Bell3, Hany Zayed3, Mark Tyrrell3, Soundrie Padayachee2.   

Abstract

OBJECTIVE: Use of colour duplex ultrasound (CDUS) and computed tomography angiography (CTA) for infrarenal endovascular aortic aneurysm repair (EVAR) surveillance differs in internationally published guidelines. This study aimed firstly to compare CDUS detection of significant sac abnormalities with CTA. Secondly, a sensitivity analysis was conducted to compare financial estimates of the, predominantly CDUS based, local and Society of Vascular Surgery (SVS) protocols, the risk stratified European Society of Vascular Surgery (ESVS) protocol, and the CTA based National Institute of Health and Care Excellence (NICE) protocol.
METHODS: Agreement between CDUS and CTA was assessed for detection of significant sac abnormalities. Surveillance protocols were extrapolated from published guidelines and applied to infrarenal EVAR patients active on local surveillance at a large, single centre. Surveillance intensity was dependent on presence of endoleak and subsequent risk of treatment failure in accordance with surveillance recommendations. Estimates for each surveillance protocol were inclusive of a range of published incidences of endoleak, contrast associated acute kidney injury (AKI), and excess hospital bed days, and estimated for a hypothetical five year surveillance period.
RESULTS: The kappa coefficient between CDUS and CTA for detecting sac abnormalities was 0.68. Maximum five year surveillance cost estimates for the 289 active EVAR patients were £272 359 for SVS, £230 708 for ESVS, £643 802 for NICE, and £266 777 for local protocols, or £1 270, £1 076, £3 003, and £1 244 per patient. Differences in endoleak incidence accounted for a 1.1 to 1.4 fold increase in costs. AKI incidence accounted for a 3.3 to 6.2 fold increase in costs.
CONCLUSION: A combined CTA and CDUS EVAR surveillance protocol, with CTA reserved for early seal assessment and confirmatory purposes, provides an economical approach without compromising detection of sac abnormalities. AKI, as opposed to direct imaging costs, accounted for the largest differences in surveillance cost estimates.
Copyright © 2021 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aortic aneurysm – abdominal; Endovascular aneurysm repair; Surveillance

Year:  2021        PMID: 34140226     DOI: 10.1016/j.ejvs.2021.04.005

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  3 in total

Review 1.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

2.  Longer follow-up intervals following endovascular aortic aneurysm repair are safe and appropriate after marked aneurysm sac regression.

Authors:  Elizabeth A Andraska; Amanda R Phillips; Katherine M Reitz; Sina Asaadi; Yancheng Dai; Edith Tzeng; Michel Makaroun; Nathan Liang
Journal:  J Vasc Surg       Date:  2022-01-29       Impact factor: 4.860

3.  An unusual cause of failure in Zenith Alpha Abdominal endograft.

Authors:  Raffaella N Berchiolli; Michele Marconi; Irene Bargellini; Giulia Bertagna; Daniele Adami; Davide M Mocellin; Roberto Cioni; Mauro Ferrari; Nicola Troisi
Journal:  Eur J Med Res       Date:  2022-03-02       Impact factor: 4.981

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.