Alauddin Bhuiyan1,2, Arun Govindaiah1, R Theodore Smith2.
Abstract
RESULTS: The system achieved an accuracy of 89.67% (sensitivity, 83.33%; specificity, 93.89%; and AUC, 0.93). For external validation, the Retinal Fundus Image Database for Glaucoma Analysis dataset, which has 638 gradable quality images, was used. Here, the model achieved an accuracy of 83.54% (sensitivity, 80.11%; specificity, 84.96%; and AUC, 0.85).Entities:
Year: 2021 PMID: 34136281 PMCID: PMC8179760 DOI: 10.1155/2021/6694784
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Figure 1The interface of “CDR annotator,” the proprietary cup/disc ratio grading software. The optic cup is circled in blue.
Figure 2(a) A 30-degree fundus image and (b) the automatically cropped optic disc region. (c) Another cropped example that is preprocessed to obtain the (d) final image.
Number of images taken from AREDS, SIMES, and RIM-ONE1. The table shows the various groups to which the images belong based on their graded cup/disc ratios.
| Category (manually graded for vertical cup/disc ratio) | AREDS | SIMES | RIM-ONE1 | Total |
|---|---|---|---|---|
| ≤0.5 | 462 | 253 | 342 | 1057 |
| Above 0.5 | 131 | 243 | 115 | 489 |
Figure 3Overall schematic representation of the model building. The two types of input images (RGB and transformed) fed into five neural networks are shown. Each network accepts a rescaled image (shown below the name of the architecture) and produces two probabilities. The ten resulting probabilities are then concatenated to form a feature array of size 10 and fed as input to a logistic model tree which acts as the final classifier in this system.
Figure 4Area under ROC of the test data results (a) and the results for the ORIGA-light dataset (b) for the two-class cup-to-disc ratio model.
Accuracy, sensitivity, specificity, Cohen's kappa, and AUC for the system with 95% confidence intervals on the test data and ORIGA-light (validation data), with the ratio over 0.5 considered as a positive case for the model.
| Measure | Test data (with 95% CI) | ORIGA-light (with 95% CI) |
|---|---|---|
| Accuracy | 89.67% (85.65% to 92.87%) | 80.11% (73.64% to 85.59%) |
| Sensitivity | 83.33% (75.44% to 89.51%) | 84.96% (81.32% to 88.12%) |
| Specificity | 93.89% (89.33% to 96.91%) | 83.54% (80.43% to 86.34%) |
| Cohen's kappa | 0.78 (0.71 to 0.85) | 0.62 (0.57 to 0.67) |
| Area under the curve | 0.93 (0.89 to 0.96) | 0.85 (0.81 to 0.90) |