Literature DB >> 34135447

A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma.

Giuseppe Giannaccare1, Marco Pellegrini2,3, Federico Bernabei4, Lara Urbini5, Fulvio Bergamini5, Lorenzo Ferro Desideri6, Alessandro Bagnis6, Francesco Biagini6, Paola Cassottana6, Chiara Del Noce6, Adriano Carnevali7, Vincenzo Scorcia7, Carlo E Traverso6, Aldo Vagge6.   

Abstract

Ultrasound cyclo plasty (UCP) is a recently developed surgical technique for glaucoma allowing a selective and controlled coagulation of the ciliary body. We herein investigated the long-term efficacy and safety of UCP for the treatment of glaucoma. This prospective study included patients with primary and secondary glaucoma. All surgeries were performed using the EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France). Sixty-six patients were included, and 60 completed regularly the 2-year follow-up. Preoperative IOP was 28.5 ± 9.6 mmHg and significantly decreased to 17.0 ± 5.4 at 2 years (p < 0.001). The daily number of both hypotensive eye drops and acetazolamide tablets decreased significantly (respectively, from 2.6 ± 1.1 to 1.7 ± 1.2 and from 0.7 ± 0.8 to 0.2 ± 0.5; both p < 0.001). At 2 years, 68.1% of patients met the definition of qualified success (IOP < 21 mmHg regardless of glaucoma medications) and 10.3% of patients met the definition of complete success (IOP < 21 mmHg without glaucoma medications). No major intra- or postoperative complications occurred; however, 15 eyes required additional glaucoma surgery. These results suggest that UCP is an effective and safe procedure to reduce IOP in glaucoma patients through a 2-year follow-up period.

Entities:  

Year:  2021        PMID: 34135447     DOI: 10.1038/s41598-021-92233-9

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  1 in total

1.  Safety and efficacy of ultrasound ciliary plasty as a primary intervention in glaucoma patients.

Authors:  Magda A Torky; Yousif A Al Zafiri; Sherein M Hagras; Abeer M Khattab; Rania M Bassiouny; Tharwat H Mokbel
Journal:  Int J Ophthalmol       Date:  2019-04-18       Impact factor: 1.779

  1 in total
  2 in total

1.  Characteristics of the Ciliary Body in Healthy Chinese Subjects Evaluated by Radial and Transverse Imaging of Ultrasound Biometric Microscopy.

Authors:  Jiawei Ren; Xinbo Gao; Liming Chen; Huishan Lin; Yao Liu; Yuying Zhou; Yunru Liao; Chunzi Xie; Chengguo Zuo; Mingkai Lin
Journal:  J Clin Med       Date:  2022-06-27       Impact factor: 4.964

2.  Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Authors:  Di Chen; Xiu-Juan Guo; Shu-Ke Luo; Yan Lu; Xiu-Rong Tang
Journal:  BMC Ophthalmol       Date:  2022-10-07       Impact factor: 2.086

  2 in total