Changes in Biceps Femoris Long Head Fascicle Length after 10-d Bed Rest Assessed with Different Ultrasound Methods.

Fabio Sarto1, Elena Monti1, Boštjan Šimunič2, Rado Pišot2, Marco V Narici, Martino V Franchi1.   

Abstract

PURPOSE: This study aimed to investigate the changes in fascicle length (Lf) of biceps femoris long head (BFlh) after 10 d of bed rest (BR) by comparing four different ultrasound (US) methods.
METHODS: Ten healthy men participated in 10-d BR. Before (BR0) and after (BR10) the BR period, BFlh Lf values were obtained using 1) extended-field-of-view (EFOV) technique, 2) the manual linear extrapolation (MLE) method, and 3) two trigonometric equations (equations A and B) from a single US image.
RESULTS: After BR10, decreased Lf values were observed by EFOV (P < 0.001; Hedges' g = 0.29) and MLE (P = 0.0082; g = 0.22) methods, but not with equations A and B. Differences between equation A and the other US methods were detected at both time points. The percentage of changes in Lf between BR0 and BR10 was influenced by the US methods applied, with difference detected between the changes measured by EFOV and the ones estimated by equation A (P = 0.04; g = 0.53). Bland-Altman analyses revealed relevant average absolute biases in Lf between EFOV and other methods at both time points (range BR0-BR10: MLE, 0.3-0.37 cm (3.4%-4.32%); equation B, 0.3-0.48 cm (3.24%-5.41%); equation A, 2.44-2.97 cm (24.05%-29.2%)). A significant correlation (r = 0.83) in percentage of change in Lf values was observed only between EFOV and MLE.
CONCLUSIONS: We showed that four distinct US methods lead to different results in the assessment of BFlh Lf changes after a short-term period of unloading. The implementation of EFOV technique (or alternatively MLE) to assess Lf changes in BFlh during longitudinal studies is warranted.
Copyright © 2021 by the American College of Sports Medicine.

Entities:  

Year:  2021        PMID: 34127637     DOI: 10.1249/MSS.0000000000002614

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  3 in total

1.  Reliability and accuracy of ultrasound image analyses completed manually versus an automated tool.

Authors:  Kealey J Wohlgemuth; Malia N M Blue; Jacob A Mota
Journal:  PeerJ       Date:  2022-06-16       Impact factor: 3.061

2.  ACSAuto-semi-automatic assessment of human vastus lateralis and rectus femoris cross-sectional area in ultrasound images.

Authors:  Paul Ritsche; Philipp Wirth; Martino V Franchi; Oliver Faude
Journal:  Sci Rep       Date:  2021-06-22       Impact factor: 4.379

3.  Physical Inactivity - the Human Health's Greatest Enemy.

Authors:  Rado Pišot
Journal:  Zdr Varst       Date:  2021-12-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.