Literature DB >> 34123492

Design of experiments for the optimization of SOFI super-resolution microscopy imaging.

Dario Cevoli1,2, Raffaele Vitale1, Wim Vandenberg1,2, Siewert Hugelier2, Robin Van den Eynde2, Peter Dedecker2, Cyril Ruckebusch1.   

Abstract

Super-resolution optical fluctuation imaging (SOFI) is a well-known super-resolution technique appreciated for its versatility and broad applicability. However, even though an extended theoretical description is available, it is still not fully understood how the interplay between different experimental parameters influences the quality of a SOFI image. We investigated the relationship between five experimental parameters (measurement time, on-time t on, off-time t off, probe brightness, and out of focus background) and the quality of the super-resolved images they yielded, expressed as Signal to Noise Ratio (SNR). Empirical relationships were modeled for second- and third-order SOFI using data simulated according to a D-Optimal design of experiments, which is an ad-hoc design built to reduce the experimental load when the total number of trials to be conducted becomes too high for practical applications. This approach proves to be more reliable and efficient for parameter optimization compared to the more classical parameter by parameter approach. Our results indicate that the best image quality is achieved for the fastest emitter blinking (lowest t on and t off), lowest background level, and the highest measurement duration, while the brightness variation does not affect the quality in a statistically significant way within the investigated range. However, when the ranges spanned by the parameters are constrained, a different set of optimal conditions may arise. For example, for second-order SOFI, we identified situations in which the increase of t off can be beneficial to SNR, such as when the measurement duration is long enough. In general, optimal values of t on and t off have been found to be highly dependent from each other and from the measurement duration.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Year:  2021        PMID: 34123492      PMCID: PMC8176802          DOI: 10.1364/BOE.421168

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  2 in total

1.  Application of Color Doppler Ultrasound in Microscopic Imaging Diagnosis of Adenomyosis.

Authors:  Jianchang Zhu; Shuang Liu; Dandan Gao
Journal:  Scanning       Date:  2022-05-31       Impact factor: 1.750

Review 2.  Technological advances in super-resolution microscopy to study cellular processes.

Authors:  Charles Bond; Adriana N Santiago-Ruiz; Qing Tang; Melike Lakadamyali
Journal:  Mol Cell       Date:  2022-01-20       Impact factor: 17.970

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.