Literature DB >> 34120296

Comparisons of the efficiency of respiratory rate monitoring devices and acoustic respiratory sound during endoscopic submucosal dissection.

Tomoko Fukada1, Yuri Tsuchiya2, Hiroko Iwakiri2, Makoto Ozaki2, Minoru Nomura2.   

Abstract

During moderate sedation for gastrointestinal endoscopic submucosal dissection (ESD), monitoring of ventilatory function is recommended. We compared the following techniques of respiratory rate (RR) measurement with respiratory sound (RRa): capnography (RRc), thoracic impedance (RRi), and plethysmograph (RRp). This study enrolled patients aged ≥ 20 years who underwent esophageal (n = 19) and colorectal (n = 5) ESDs. RRc, RRi, RRp, and RRa were measured by Capnostream™ 20P, BSM-2300, Nellcor™ PM1000N, and Radical-7®, respectively. In total, 413 RR data were collected from the esophageal ESD group and 114 RR data were collected from the colorectal ESD group. Compared with RRa during colorectal ESD, that during esophageal ESD had larger bias [95% limit of agreement (LOA)] with RRc [1.9 (- 11.0-14.8) vs. - 0.4 (- 2.9-2.2)], RRi [9.4 (- 16.8-9.4) vs. - 1.5 (- 12.0-8.9)], and RRp [0.3 (- 5.7-6.4) vs. 0.2 (- 3.2-3.6)]. Of the correct RR values displayed during esophageal ESD, > 90% were measured as RRa and RRp. Moreover, RRc was a useful parameter during colorectal ESD. To maximize patient safety during ESD under sedation, endoscopists and medical staff should know the feature and principle of the devices used for RR measurement. During esophageal ESD, RRa and RRp may be a good parameter to detect bradypnea or apnea. RRc, RRa and RRp are useful for reliable during colorectal ESD.Trial registration UMIN-CTR (UMIN000025421).
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Acoustic respiratory sound; Capnography; Endoscopic submucosal dissection; Plethysmograph; Respiratory rate; Thoracic impedance

Mesh:

Year:  2021        PMID: 34120296     DOI: 10.1007/s10877-021-00727-8

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  6 in total

1.  Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices?

Authors:  John H Burton; John D Harrah; Carl A Germann; Douglas C Dillon
Journal:  Acad Emerg Med       Date:  2006-03-28       Impact factor: 3.451

2.  Safety and efficacy of carbon dioxide insufflation during gastric endoscopic submucosal dissection.

Authors:  Jun Takada; Hiroshi Araki; Fumito Onogi; Takayuki Nakanishi; Masaya Kubota; Takashi Ibuka; Masahito Shimizu; Hisataka Moriwaki
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

3.  Capnography accurately detects apnea during monitored anesthesia care.

Authors:  Roy G Soto; Eugene S Fu; Hector Vila; Rafael V Miguel
Journal:  Anesth Analg       Date:  2004-08       Impact factor: 5.108

4.  The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry.

Authors:  Michael A E Ramsay; Mohammad Usman; Elaine Lagow; Minerva Mendoza; Emylene Untalan; Edward De Vol
Journal:  Anesth Analg       Date:  2013-04-30       Impact factor: 5.108

5.  Pulse oximetry-derived respiratory rate in general care floor patients.

Authors:  Paul S Addison; James N Watson; Michael L Mestek; James P Ochs; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-05-06       Impact factor: 2.502

Review 6.  Duodenal Rare Neuroendocrine Tumor: Clinicopathological Characteristics of Patients with Gangliocytic Paraganglioma.

Authors:  Yoichiro Okubo; Tomoyuki Yokose; Osamu Motohashi; Yohei Miyagi; Emi Yoshioka; Masaki Suzuki; Kota Washimi; Kae Kawachi; Madoka Nito; Tetsuo Nemoto; Kazutoshi Shibuya; Yoichi Kameda
Journal:  Gastroenterol Res Pract       Date:  2016-12-21       Impact factor: 2.260

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.