Literature DB >> 34118760

Highly permselective uric acid detection using kidney cell membrane-functionalized enzymatic biosensors.

Insu Kim1, Young Im Kim2, Sang Won Lee1, Hyo Gi Jung3, Gyudo Lee4, Dae Sung Yoon5.   

Abstract

Abnormal blood uric acid (UA) levels can lead to its crystallization in the joints, consequently resulting in gout. Accurate detection of UA in the blood is imperative for the early diagnosis of gout. However, electrochemical UA biosensors are vulnerable to antioxidants in the blood, limiting accurate UA detection. To address this issue, we focused on the function of uric acid transporter 1 (URAT1), which is selectively permeable to UA. URAT1 is abundant in the kidney cell membrane (KCM). To apply URAT1 to a sensor, we developed a KCM-coated UA biosensor (called the KCM sensor) that could selectively detect UA through URAT1. The KCM coating in the fabricated KCM sensor was verified via scanning electron microscopy, atomic force microscopy, and confocal microscopy. The KCM sensor enabled the detection of UA in the range of 0-1000 μM, with a limit of detection of 8.5 μM, suggesting that it allows the diagnosis of the early stages of gout. On the other hand, the UA permeability of the KCM sensor was significantly reduced in the presence of a URAT1 inhibitor, implying that URAT1 is a key factor for UA detection. The selectivity of the KCM sensor was demonstrated by measuring the amount for UA in the presence of various antioxidants. Finally, the KCM sensor was capable of measuring UA in human serum and was reproducible with 0.5-1.6% deviation. The UA permeability and selectivity of the KCM sensor were maintained even after 3 weeks of storage.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical detection; Kidney cell membrane; Permselectivity; Urate transporter 1; Uric acid biosensor; Uric acid oxidase

Year:  2021        PMID: 34118760     DOI: 10.1016/j.bios.2021.113411

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A Micro Electrochemical Sensor for Multi-Analyte Detection Based on Oxygenated Graphene Modified Screen-Printed Electrode.

Authors:  Baiqing Yuan; Liju Gan; Gang Li; Chunying Xu; Gang Liu
Journal:  Nanomaterials (Basel)       Date:  2022-02-21       Impact factor: 5.076

2.  Highly Sensitive Uric Acid Detection Based on a Graphene Chemoresistor and Magnetic Beads.

Authors:  Wangyang Zhang; Xiaoqiang Zhao; Lina Diao; Hao Li; Zhonghao Tong; Zhiqi Gu; Bin Miao; Zhan Xu; Han Zhang; Yue Wu; Jiadong Li
Journal:  Biosensors (Basel)       Date:  2021-08-29
  2 in total