Literature DB >> 34117945

Perylene diimide/MXene-modified graphitic pencil electrode-based electrochemical sensor for dopamine detection.

Umay Amara1,2, Muhammad Taqi Mehran3, Bilal Sarfaraz3, Khalid Mahmood4, Akhtar Hayat1, Muhammad Nasir1, Sara Riaz5, Mian Hasnain Nawaz6.   

Abstract

The synthesis of novel architecture comprising perylene diimide (PDI)-MXene (Ti3C2TX)-integrated graphitic pencil electrode for electrochemical detection of dopamine (DA) is reported. The good electron passage between PDI-MXene resulted in an unprecedented nano-adduct bearing enhanced electrocatalytic activity with low-energy electronic transitions. The anionic groups of PDI corroborated enhanced active surface area for selective binding and robust oxidation of DA, thereby decreasing the applied potential. Meanwhile, the MXene layers acted as functional conducive support for PDI absorption via strong H-bonding. The considerable conductivity of MXene enhanced electron transportation thus increasing the sensitivity of sensing interface. The inclusively engineered nano-adduct resulted in robust DA oxidation with ultra-sensitivity (38.1 μAμM-1cm-2), and low detection limit (240 nM) at very low oxidation potential (-0.135 V). Moreover, it selectively signaled DA in the presence of physiological interferents with wide linearity (100-1000 μM). The developed transducing interface performed well in human serum samples with RSD (0.1 to 0.4%) and recovery (98.6 to 100.2%) corroborating the viability of the practical implementation of this integrated system. Graphical abstract Schematic illustration of the oxidative process involved on constructed sensing interface for the development of a non-enzymatic dopamine sensor.

Entities:  

Keywords:  Dopamine; Electrochemical sensor; Low oxidation potential; MXene; Perylene diimide; Serum sample analysis

Mesh:

Substances:

Year:  2021        PMID: 34117945     DOI: 10.1007/s00604-021-04884-0

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  30 in total

1.  Environment-Sensitive Photoresponse of Spontaneously Partially Oxidized Ti3C2 MXene Thin Films.

Authors:  Sergii Chertopalov; Vadym N Mochalin
Journal:  ACS Nano       Date:  2018-06-13       Impact factor: 15.881

2.  Low-Power and High-Performance Trimethylamine Gas Sensor Based on n-n Heterojunction Microbelts of Perylene Diimide/CdS.

Authors:  Peihua Zhu; Yucheng Wang; Pan Ma; Shanshan Li; Fuqing Fan; Kang Cui; Shenguang Ge; Yan Zhang; Jinghua Yu
Journal:  Anal Chem       Date:  2019-03-28       Impact factor: 6.986

3.  Electrochemical dual signal sensing platform for the simultaneous determination of dopamine, uric acid and glucose based on copper and cerium bimetallic carbon nanocomposites.

Authors:  Rui Li; Huanru Liang; Mingfang Zhu; Mushen Lai; Shumei Wang; Hongwu Zhang; Hongqing Ye; Rongkun Zhu; Wenhao Zhang
Journal:  Bioelectrochemistry       Date:  2021-01-18       Impact factor: 5.373

4.  Large-Area MXene Electrode Array for Flexible Electronics.

Authors:  Benzheng Lyu; Minje Kim; Hongyue Jing; Joohoon Kang; Chuan Qian; Sungjoo Lee; Jeong Ho Cho
Journal:  ACS Nano       Date:  2019-09-30       Impact factor: 15.881

5.  Molecularly imprinted polymer-decorated signal on-off ratiometric electrochemical sensor for selective and robust dopamine detection.

Authors:  Jiao Yang; Yue Hu; Yingchun Li
Journal:  Biosens Bioelectron       Date:  2019-03-29       Impact factor: 10.618

6.  Synthesis, Characterization, Physical Properties, and OLED Application of Single BN-Fused Perylene Diimide.

Authors:  Gang Li; Yongbiao Zhao; Junbo Li; Jun Cao; Jia Zhu; Xiao Wei Sun; Qichun Zhang
Journal:  J Org Chem       Date:  2014-12-10       Impact factor: 4.354

7.  Directed evolution of a magnetic resonance imaging contrast agent for noninvasive imaging of dopamine.

Authors:  Mikhail G Shapiro; Gil G Westmeyer; Philip A Romero; Jerzy O Szablowski; Benedict Küster; Ameer Shah; Christopher R Otey; Robert Langer; Frances H Arnold; Alan Jasanoff
Journal:  Nat Biotechnol       Date:  2010-02-28       Impact factor: 54.908

8.  Unraveling and Regulating Self-Discharge Behavior of Ti3C2Tx MXene-Based Supercapacitors.

Authors:  Zixing Wang; Zhong Xu; Haichao Huang; Xiang Chu; Yanting Xie; Da Xiong; Cheng Yan; Haibo Zhao; Haitao Zhang; Weiqing Yang
Journal:  ACS Nano       Date:  2020-03-23       Impact factor: 15.881

9.  A highly flexible and sensitive piezoresistive sensor based on MXene with greatly changed interlayer distances.

Authors:  Yanan Ma; Nishuang Liu; Luying Li; Xiaokang Hu; Zhengguang Zou; Jianbo Wang; Shijun Luo; Yihua Gao
Journal:  Nat Commun       Date:  2017-10-31       Impact factor: 14.919

Review 10.  Dopamine System Dysregulation in Major Depressive Disorders.

Authors:  Pauline Belujon; Anthony A Grace
Journal:  Int J Neuropsychopharmacol       Date:  2017-12-01       Impact factor: 5.176

View more
  1 in total

1.  Copper oxide integrated perylene diimide self-assembled graphitic pencil for robust non-enzymatic dopamine detection.

Authors:  Umay Amara; Sara Riaz; Khalid Mahmood; Naeem Akhtar; Muhammad Nasir; Akhtar Hayat; Muhammad Khalid; Muhammad Yaqub; Mian Hasnain Nawaz
Journal:  RSC Adv       Date:  2021-07-19       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.