| Literature DB >> 34113877 |
Bolanle Akinyele1, Joseph E Marine1, Charles Love1, Thomas C Crawford2, Jonathan Chrispin1, Stephen C Vlay3, David D Spragg1, Kim A Eagle2, Ronald D Berger1, Hugh Calkins1, Gordon F Tomaselli4, Sunil K Sinha1.
Abstract
BACKGROUND: An estimated 1 million patients require cardiac implantable electronic devices (CIEDs) but go without annually. This disparity exists in low-to-middle-income nations largely owing to the cost of CIED hardware. Humanitarian reuse of CIEDs has been shown to be safe and feasible. However, recent publications have raised concern that promotion of CIED reuse may foster a CIED "black market," to the dismay of manufacturers, regulators, and clinicians alike.Entities:
Keywords: Cardiac implantable electronic device (CIED); Defibrillator re-use; Global disparities; Implantable cardioverter-defibrillator; Pacemaker; Pacemaker re-use
Year: 2020 PMID: 34113877 PMCID: PMC8183896 DOI: 10.1016/j.hroo.2020.06.007
Source DB: PubMed Journal: Heart Rhythm O2 ISSN: 2666-5018
Specific characteristics of each online sale listing of cardiac implantable electronic devices in the United States during the 6-month observational study period
| Website | US seller location (state) | CIED type | Model | Product year | N | Serial # | Online price (USD) | Time on listing (weeks) | Manufacturer and status |
|---|---|---|---|---|---|---|---|---|---|
| MedWOW | NC | ICD | Evera MRI XT DR SureScan | 2017 | 35 | No | $100 | 8 weeks | Medtronic |
| MedWOW | MN | PPM | Adapta ADSR01 | 2016 | 1 | Yes | $500 | 26+ | Medtronic |
| eBay | KY | PPM | Accent SR RF PM1210 | 2012 | 1 | Yes | $275 | 8 weeks | Abbott |
| DOTmed | FL | PPM | Adapta ADDR01 | 2013 | 2 | Yes | $700 | 26+ | Medtronic |
| DOTmed | FL | PPM | Adapta ADSR01 | 2014 | 1 | Yes | $700 | 26+ | Medtronic |
| DOTmed | FL | ICD | Ellipse VR CD1411-36Q | 2016 | 2 | Yes | $700 | 10 weeks | Abbott |
| MedWOW | CA | ICD | Iperia 7 DR-T | 2018 | 10 | No | $1000 | 20+ | Biotronik |
| MedWOW | CA | PPM | Entovis SR-T | 2018 | 1 | No | $1500 | 19+ | Biotronik |
| DOTmed | WA | PPM | Accolade MRI DR EL L331 | 2017 | 3 | Yes | $1197 | 5 weeks | Boston Scientific |
| DOTmed | WA | PPM | Accolade MRI DR L311 | 2017 | 2 | Yes | $1151 | 5 weeks | Boston Scientific |
CIED = cardiac implantable electronic device; ICD = implantable cardioverter-defibrillator; PPM = permanent pacemaker.
Inadequate images but credible e-mail correspondence regarding authenticity.
Figure 1Number of unregulated online sale listings of verified cardiac implantable electronic devices (CIEDs) in the United States (per month) over the 6-month study period. Telephone icon signifies communication with manufacturers verifying the status of their listed CIEDs; magnifying glass icon signifies that new CIED listings were observed in the first 3 months of study (positive magnifying glass) but not in the last 3 months of study (negative magnifying glass). ICD = implantable cardioverter-defibrillator; PPM = permanent pacemaker.