Literature DB >> 34112908

High-performance dialyzers and mortality in maintenance hemodialysis patients.

Masanori Abe1,2, Ikuto Masakane3,4, Atsushi Wada3,5, Shigeru Nakai3,6, Eiichiro Kanda3,7, Kosaku Nitta3,8, Hidetomo Nakamoto3,9.   

Abstract

Few data are available regarding the association of dialyzer type with prognosis. In Japan, dialyzers are classified as types I, II, III, IV, and V based on β2-microglobulin clearance rates of < 10, < 30, < 50, < 70, and ≥ 70 mL/min, respectively. We investigated the relationship of the 5 dialyzer types with 1-year mortality. This nationwide cohort study used data collected at the end of 2008 and 2009 by the Japanese Society for Dialysis Therapy Renal Data Registry. We enrolled 203,008 patients on maintenance hemodialysis who underwent hemodialysis for at least 1 year and were managed with any of the 5 dialyzer types. To evaluate the association of dialyzer type with 1-year all-cause mortality, Cox proportional hazards models and propensity score-matched analyses were performed. After adjustment of the data with clinicodemographic factors, the type I, II, and III groups showed significantly higher hazard ratios (HRs) than the type IV dialyzers (reference). After adjustment for Kt/V and β2-microglobulin levels, the HRs were significantly higher in the type I and II groups. After further adjustment for nutrition- and inflammation-related factors, the HRs were not significantly different between the type IV and type I and II groups. However, type V dialyzers consistently showed a significantly lower HR. With propensity score matching, the HR for the type V dialyzer group was significantly lower than that for the type IV dialyzer group. Additional long-term trials are required to determine whether type V dialyzers, which are high-performance dialyzers, can improve prognosis.

Entities:  

Year:  2021        PMID: 34112908     DOI: 10.1038/s41598-021-91751-w

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  2 in total

1.  EBPG guideline on dialysis strategies.

Authors:  James Tattersall; Alejandro Martin-Malo; Luciano Pedrini; Ali Basci; Bernard Canaud; Denis Fouque; Patrick Haage; Klaus Konner; Jeroen Kooman; Francesco Pizzarelli; Jan Tordoir; Marianne Vennegoor; Christoph Wanner; Piet ter Wee; Raymond Vanholder
Journal:  Nephrol Dial Transplant       Date:  2007-05       Impact factor: 5.992

2.  Performance of hemodialysis with novel medium cut-off dialyzers.

Authors:  Alexander H Kirsch; Raphael Lyko; Lars-Göran Nilsson; Werner Beck; Michael Amdahl; Petra Lechner; Andreas Schneider; Christoph Wanner; Alexander R Rosenkranz; Detlef H Krieter
Journal:  Nephrol Dial Transplant       Date:  2017-01-01       Impact factor: 5.992

  2 in total
  1 in total

1.  Dialyzer surface area is a significant predictor of mortality in patients on hemodialysis: a 3-year nationwide cohort study.

Authors:  Masanori Abe; Ikuto Masakane; Atsushi Wada; Shigeru Nakai; Kosaku Nitta; Hidetomo Nakamoto
Journal:  Sci Rep       Date:  2021-10-18       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.