| Literature DB >> 34110427 |
Heinrich A Backmann1, Marthe Larsen2, Anders S Danielsen2, Solveig Hofvind3,4.
Abstract
OBJECTIVE: To analyze the association between radiologists' performance and image position within a batch in screen reading of mammograms in Norway.Entities:
Keywords: Breast; Mammography; Radiology; Screening; Sensitivity and specificity
Mesh:
Year: 2021 PMID: 34110427 PMCID: PMC8589803 DOI: 10.1007/s00330-021-08010-9
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315
Fig. 1Study population, exclusions, and final study sample
Fig. 2Mammograms (mediolateral oblique and craniocaudal view) of a woman’s right and left breast with an interpretation score of 1 by both radiologists
Frequencies (n) and proportions (% or per 1000 readings) of readings, true positive (TP), false positive (FP), true negative (TN), false negative (FN), sensitivity of the radiologists (, and specificity () of the radiologists for each category of image position
| Image position | Readings | True positive | False positive | True negative | False negative | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| % | Per 1000 | % | % | Per 1000 | % | % | ||||||
| 1–3 | 210,425 | 7.2 | 1510 | 7.2 | 13,676 | 6.5 | 195,128 | 92.7 | 111 | 0.53 | 93.2 | 93.4 |
| 4–16 | 715,021 | 24.3 | 3084 | 4.3 | 34,800 | 4.9 | 676,748 | 94.7 | 389 | 0.54 | 88.8 | 95.1 |
| 17–33 | 648,840 | 22.1 | 2616 | 4.0 | 28,506 | 4.4 | 617,355 | 95.2 | 363 | 0.56 | 87.8 | 95.6 |
| 34–66 | 692,092 | 23.6 | 2724 | 3.9 | 28,195 | 4.1 | 660,735 | 95.5 | 438 | 0.63 | 86.2 | 95.9 |
| > 66 | 670,934 | 22.8 | 2530 | 3.8 | 23,241 | 3.5 | 644,671 | 96.1 | 492 | 0.73 | 83.7 | 96.5 |
| Total | 2,937,312 | 100.0 | 12,464 | 4.2 | 128,418 | 4.4 | 2,794,637 | 95.1 | 1793 | 0.61 | 87.4 | 95.6 |
Fig. 3Mean proportion of true positive, false positive, true negative, and false negative for image positions 1 to 100 by the first reader and second reader
Frequencies (n) and proportions (% or per 1000 readings) of batches, readings, true positive, false positive, true negative, and false negative for each category of total batch size
| Batch size | Batches | Readings | True positive | False positive | True negative | False negative | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| % | % | Per 1000 | % | % | Per 1000 | |||||||
| 1 | 5577 | 7.5 | 5577 | 0.2 | 266 | 47.7 | 655 | 11.7 | 4655 | 83.5 | 1 | 0.18 |
| 2–40 | 43,690 | 58.4 | 746,303 | 25.4 | 3654 | 4.9 | 39,929 | 5.4 | 702,313 | 94.1 | 407 | 0.55 |
| 41–72 | 13,582 | 18.2 | 733,345 | 25.0 | 3039 | 4.1 | 32,974 | 4.5 | 696,912 | 95.0 | 420 | 0.57 |
| 73–120 | 7846 | 10.5 | 720,030 | 24.5 | 2868 | 4.0 | 29,176 | 4.1 | 687,522 | 95.5 | 464 | 0.64 |
| > 120 | 4073 | 5.5 | 732,057 | 24.9 | 2637 | 3.6 | 25,684 | 3.5 | 703,235 | 96.1 | 501 | 0.68 |
| Total | 74,768 | 100.0 | 2,937,312 | 100.0 | 12,464 | 4.2 | 128,418 | 4.4 | 2,794,637 | 95.1 | 1,793 | 0.61 |
Predicted proportions (% or per 100 readings) of true positive, false positive, true negative, false negative, sensitivity, and specificity of the radiologists for different image positions within a batch of screen readings
| Image position | True positive, per 1000 | False positive, % | True negative, % | False negative, per 1000 | Sensitivity of the radiologists’ scores, % | Specificity for the radiologists’ scores, % |
|---|---|---|---|---|---|---|
| 10 | 4.0 (3.8–4.2) | 5.4 (4.8–5.9) | 94.4 (94.0–94.8) | 0.60 (0.53–0.67) | 88.6 (87.6–89.5) | 94.8 (94.4–95.2) |
| 20 | 4.0 (3.7–4.2) | 5.3 (4.7–5.8) | 94.5 (94.1–94.9) | 0.60 (0.53–0.67) | 88.4 (87.4–89.4) | 94.9 (94.5–95.3) |
| 30 | 4.0 (3.8–4.2) | 5.2 (4.7–5.7) | 94.6 (94.2–94.9) | 0.61 (0.54–0.68) | 88.2 (87.2–89.2) | 95.0 (94.6–95.4) |
| 40 | 4.0 (3.7–4.2) | 5.1 (4.6–5.6) | 94.6 (94.3 –95.0) | 0.61 (0.54–0.68) | 88.0 (87.0–89.0) | 95.1 (94.7–95.5) |
| 50 | 3.9 (3.7–4.1) | 5.0 (4.5–5.5) | 94.7 (94.4–95.1) | 0.62 (0.54–0.69) | 87.8 (86.8–88.8) | 95.2 (94.8–95.5) |
| 60 | 3.9 (3.7–4.1) | 4.9 (4.4–5.4) | 94.8 (94.4–95.2) | 0.62 (0.55–0.69) | 87.7 (86.6–88.7) | 95.2 (94.9–95.6) |
| 70 | 3.9 (3.7–4.1) | 4.9 (4.4–5.5) | 94.9 (94.5–95.3) | 0.62 (0.55–0.70) | 87.5 (86.4–88.5) | 95.3 (94.9–95.6) |
| 80 | 3.9 (3.6–4.1) | 4.8 (4.3–5.3) | 95.0 (94.6–95.3) | 0.63 (0.55–0.70) | 87.3 (86.2–88.3) | 95.4 (95.0–95.7) |
| 90 | 3.8 (3.6–4.0) | 4.7 (4.3–5.2) | 95.0 (94.7–95.4) | 0.63 (0.56–0.71) | 87.1 (86.0–88.1) | 95.5 (95.1–95.8) |
| 100 | 3.8 (3.6–4.0) | 4.6 (4.1–5.1) | 95.1 (94.8–95.5) | 0.64 (0.56–0.72) | 86.9 (85.8–88.0) | 95.5 (95.2–95.9) |
| 150 | 3.7 (3.4–3.9) | 4.3 (3.8–4.7) | 95.5 (95.2–95.8) | 0.66 (0.57–0.76) | 85.9 (84.7–87.0) | 95.9 (95.6–96.2) |
| 200 | 3.6 (3.3–3.9) | 3.9 (3.5–4.3) | 95.8 (95.5–96.1) | 0.69 (0.57–0.81) | 84.8 (83.5–86.0) | 96.2 (95.9–96.5) |
| 300 | 3.4 (3.0–3.8) | 3.3 (2.9–3.7) | 96.4 (96.1–96.7) | 0.74 (0.56–0.92) | 82.4 (81.0–83.8) | 96.8 (97.1–96.6) |