A sensitive gas chromatographic assay with electron-capture detection has been developed for sulfamic acid diester (sulfamic acid 1,7-heptanediyl ester, NSC 329680) based on its conversion to 1,7-diiodoheptane in the presence of excess sodium iodide. The assay is linear up to 1 microgram/ml sulfamic acid diester and has a lower limit of detection of 25 ng/ml from 0.5 ml plasma. The coefficient of variation of the assay is 6.4% at 1 microgram/ml and 8.0% at 100 ng/ml. Sulfamic acid diester is relatively stable in 0.9% sodium chloride and 0.1 M sodium phosphate buffers, pH 7.0-9.0, with half-lives greater than 38 h. The major breakdown product of sulfamic acid diester is sulfamic acid 1,7-heptane-monoyl ester. When added to whole blood sulfamic acid diester shows concentration-dependent breakdown. At 50 and 100 micrograms/ml sulfamic acid diester, the half-time in whole blood is 6.9 h and 65% of the drug is sequestered by the blood cells. At 10 micrograms/ml sulfamic acid diester in blood, there is no detectable breakdown of the drug over 24 h and all of the drug is sequestered by the blood cells. Protein binding of sulfamic acid diester in human plasma is 82% at 10 micrograms/ml and 68% at 100 micrograms/ml.Entities:
Mesh:
Substances:
Year: 1988 PMID: 3410909 DOI: 10.1016/0378-4347(88)80127-0
Source DB: PubMed Journal: J Chromatogr