| Literature DB >> 34108501 |
Naren Vikram Raj Masna1, Junjun Huan1, Soumyajit Mandal1, Swarup Bhunia2.
Abstract
Automatic recognition of unique characteristics of an object can provide a poweEntities:
Year: 2021 PMID: 34108501 PMCID: PMC8190304 DOI: 10.1038/s41598-021-91531-6
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1(a) Overview of the signature generation process for material biometrics. Custom tagged filament is created by mixing acrylonitrile butadiene styrene (ABS) with an NQR-sensitive material. Tagged and normal (un-tagged) filaments are dispensed by a dual-filament 3D printer to generate arbitrary 3D spatial tagging patterns within the printed object. (b) Flowchart of the general process for product authentication using a cloud database and signature information read from the embedded tags [Microsoft Visio].
Figure 2Spin echoes from pulsed NQR measurements using the spin-locked spin echo (SLSE) sequence[15] are collected, filtered, and fitted to exponential decay curves. Assuming a mono-exponential decay, the resulting function contains three useful features. (a) Typical echo spectrum (shown as a function of frequency offset from the nominal resonance frequency). The first feature is the peak signal amplitude A, which is proportional to the number of quadrupolar nuclei within the tag. The second feature is the frequency-domain linewidth . (b) Typical echo decay curve. The third feature is the decay time constant , which defines the time taken by spin coherences to decay after being excited by resonant RF pulses.
Figure 3(a) Spatially-selective detection using an array of hollow solenoid coils. The system measures signatures from N groups of tags near-simultaneously by using a 1 : N analog multiplexer. (b) Signatures from M tags within each group can be measured per scan using relaxation-based imaging. Thus, a total of tags can be measured by combining the two techniques. (c) A normal SLSE pulse sequence for signature read-out which requires a wait-time of . (d) A multiplexed SLSE pulse sequence that allows signature from other tags to be acquired during [Microsoft Visio].
Figure 4(a) Signatures from specific parts of the sample are read out using a spatially-selective “hollow coil” detector; each signature has a different value of the peak amplitude A. The number on the label represents the relative amount of used for tagging. (b) Cylindrical samples containing three tagging locations, each using 10% filament. The figure shows three of the possible binary patterns and their field-dependent relaxation decays. (c) Signature prediction accuracy of different machine learning (ML)-based classification methods (listed on the figure). (d) Measured improvement in prediction accuracy with increase in SNR for 3-bit patterns (10% ) [Microsoft Visio].
Figure 5(a) The original STL design of “the Statue of Liberty”. (b) The modified design used to embed an NQR-sensitive signature within the object. (c) A cross-sectional view of the modified design, showing the space to be occupied by the tags. (d) A typical signature pattern printed using two different colors (white representing tagged filament, and green representing regular filament). The signature contains 15 tags, with each tag encoding amplitude bit. The modified object and signature can either be printed together, or the latter can be inserted as an add-on after printing the object. (e) The resultant 3D-printed object containing the embedded material biometrics signature [Microsoft Visio].
Figure 6(a) The basic experimental setup, which consists of a bench-top MR spectrometer (Magritek Kea2), duplexer rack, impedance matching network, and solenoid coil. (b) A single spatially-selective detector (diameter mm, length mm, 13 turns) wound using AWG 20 copper wire. This particular version was designed to scan small objects (diameter mm) that fit within the detector. (c) Block diagram of the analog front-end (AFE) used to read-out embedded NQR-active signatures. A total of spatially-selective detectors is shown. Here PA power amplifier (used to generate RF pulses) and LNA low-noise amplifier (used to amplify the resulting spin echoes). (d) Modified experimental setup used for relaxation-based imaging. A set of Helmholtz coils is used to generate the necessary static field gradient [Microsoft Visio].