Abstract
Zero-valent iron (ZVI)- and zero-valent aluminium (ZVA)-activated persulfate (PS) oxidation procedure was applied to remove the industrial pollutants 3,5-dichlorophenol (3,5-DCP; 12.27 µM) and 2,4-dichloroaniline (2,4-DCA; 12.34 µM) from aqueous solutions. The effects of PS concentration and pH were investigated to optimize heterogeneous treatment systems. Negligible removals were obtained for both pollutants by individual applications of nanoparticles (1 g/L) and PS (1.00 mM). PS activation with ZVI resulted in 59% (1.00 mM PS; 1 g/L ZVI; pH 5.0; 120 min) and 100% (0.75 mM PS; 1 g/L ZVI; pH 5.0; 80 min) 3,5-DCP and 2,4-DCA removals, respectively. The ZVA/PS treatment system gave rise to only 31% 3,5-DCP (1.00 mM PS; 1 g/L ZVA; pH 3.0; 120 min) and 47% 2,4-DCA (0.25 mM PS; 1 g/L ZVA; pH 3.0; 120 min) removals. The pH decreases from 5.0 to 3.0 and from 3.0 to 1.5 enhanced contaminant removals for ZVI/PS and ZVA/PS treatments, respectively. Pollutant removal rates were in correlation with the consumption rates of the oxidants. Metal ion (Al, Fe) release increased in the presence of PS and with decreasing pH.Entities:
Keywords: 2,4-dichloroaniline; 3,5-dichlorophenol; advanced oxidation; persulfate activation with zero-valent metals; sulfate radicals
Year: 2021 PMID: 34104043 PMCID: PMC8164209 DOI: 10.3906/kim-1911-60
Source DB: PubMed Journal: Turk J Chem ISSN: 1300-0527 Impact factor: 1.239
Fe concentrations obtained after 120 min treatment of 3,5-DCP and 2,4-DCA with ZVI/air/H+ and ZVI/PS systems. Experimental conditions: 3,5-DCP and 2,4-DCA = 2 mg/L, PS = 0.50 mM, ZVI = 1 g/L.
| Pollutant | Process | Total Fe (mg/L) |
|---|---|---|
| 3,5-DCP | ZVI, pH 5.0 | 0.51 |
| ZVI/PS, pH 5.0 | 22 | |
| ZVI/PS, pH 3.0 | 50 | |
| 2,4-DCA | ZVI, pH 5.0 | 0.22 |
| ZVI/PS, pH 5.0 | 0.24 | |
| ZVI/PS, pH 3.0 | 12 |
Al concentrations obtained after 120 min treatment of 3,5-DCP and 2,4-DCA with ZVA/air/H+ and ZVA/PS systems. Experimental conditions: 3,5-DCP and 2,4-DCA = 2 mg/L, PS = 0.50 mM, ZVA = 1 g/L.
| Pollutant | Process | Total Al (mg/L) |
|---|---|---|
| 3,5-DCP | ZVA, pH 3.0 | 4.2 |
| ZVA/PS, pH 3.0 | 3.9 | |
| ZVA/PS, pH 1.5 | 17 | |
| 2,4-DCA | ZVA, pH 3.0 | 4.5 |
| ZVA/PS, pH 3.0 | 4.5 | |
| ZVA/PS, pH 1.5 | 20 |