Literature DB >> 34099062

3D Printed frames to enable reuse and improve the fit of N95 and KN95 respirators.

Malia McAvoy1,2, Ai-Tram N Bui1,3, Christopher Hansen1,4, Deborah Plana1,5,6, Jordan T Said1,3, Zizi Yu1,3, Helen Yang1,7, Jacob Freake1,8, Christopher Van1,9, David Krikorian1,10, Avilash Cramer1,5, Leanne Smith1,9, Liwei Jiang1,11, Karen J Lee12, Sara J Li12, Brandon Beller1,13, Kimberley Huggins4, Michael P Short1,14, Sherry H Yu1,15, Arash Mostaghimi1,3,12, Peter K Sorger16,17,18, Nicole R LeBoeuf19,20,21,22.   

Abstract

BACKGROUND: In response to supply shortages caused by the COVID-19 pandemic, N95 filtering facepiece respirators (FFRs or "masks"), which are typically single-use devices in healthcare settings, are routinely being used for prolonged periods and in some cases decontaminated under "reuse" and "extended use" policies. However, the reusability of N95 masks is limited by degradation of fit. Possible substitutes, such as KN95 masks meeting Chinese standards, frequently fail fit testing even when new. The purpose of this study was to develop an inexpensive frame for damaged and poorly fitting masks using readily available materials and 3D printing.
RESULTS: An iterative design process yielded a mask frame consisting of two 3D printed side pieces, malleable wire links that users press against their face, and cut lengths of elastic material that go around the head to hold the frame and mask in place. Volunteers (n = 45; average BMI = 25.4), underwent qualitative fit testing with and without mask frames wearing one or more of four different brands of FFRs conforming to US N95 or Chinese KN95 standards. Masks passed qualitative fit testing in the absence of a frame at rates varying from 48 to 94 % (depending on mask model). For individuals who underwent testing using respirators with broken or defective straps, 80-100 % (average 85 %) passed fit testing with mask frames. Among individuals who failed fit testing with a KN95, ~ 50 % passed testing by using a frame.
CONCLUSIONS: Our study suggests that mask frames can prolong the lifespan of N95 and KN95 masks by serving as a substitute for broken or defective bands without adversely affecting fit. Use of frames made it possible for ~ 73 % of the test population to achieve a good fit based on qualitative and quantitative testing criteria, approaching the 85-90 % success rate observed for intact N95 masks. Frames therefore represent a simple and inexpensive way of expanding access to PPE and extending their useful life. For clinicians and institutions interested in mask frames, designs and specifications are provided without restriction for use or modification. To ensure adequate performance in clinical settings, fit testing with user-specific masks and PanFab frames is required.

Entities:  

Keywords:  3D printing; COVID-19; KN95 masks; N95 respirators; filtering face piece (FFP) respirator; mask frames; occupational health; pandemic response; personal protective equipment (PPE); prototyping

Year:  2021        PMID: 34099062     DOI: 10.1186/s42490-021-00055-7

Source DB:  PubMed          Journal:  BMC Biomed Eng        ISSN: 2524-4426


  4 in total

1.  Improving the fit of filtering facepiece respirators.

Authors:  Kamini Shah; Stefan Serban; Gail V A Douglas
Journal:  Br Dent J       Date:  2022-08-05       Impact factor: 2.727

2.  Effectiveness of a 3D-printed mask fitter in an Ophthalmology setting during COVID-19.

Authors:  John Liu; Jingyi Ma; Iqbal Ik Ahmed; Devesh K Varma
Journal:  Can J Ophthalmol       Date:  2021-03-19       Impact factor: 2.592

3.  Aging of 3D Printed Polymers under Sterilizing UV-C Radiation.

Authors:  Catalin Gheorghe Amza; Aurelian Zapciu; Florin Baciu; Mihai Ion Vasile; Diana Popescu
Journal:  Polymers (Basel)       Date:  2021-12-20       Impact factor: 4.329

Review 4.  A position statement and practical guide to the use of particulate filtering facepiece respirators (N95, FFP2, or equivalent) for South African health workers exposed to respiratory pathogens including Mycobacterium tuberculosis and SARS-CoV-2.

Authors:  K Dheda; S Charalambous; A S Karat; A von Delft; U G Lalloo; R van Zyl Smit; R Perumal; B W Allwood; A Esmail; M L Wong; A G Duse; G Richards; C Feldman; M Mer; K Nyamande; U Lalla; C F N Koegelenberg; F Venter; H Dawood; S Adams; N A B Ntusi; H-M van der Westhuizen; M-Y S Moosa; N A Martinson; H Moultrie; J Nel; H Hausler; W Preiser; L Lasersohn; H J Zar; G J Churchyard
Journal:  Afr J Thorac Crit Care Med       Date:  2021-10-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.