| Literature DB >> 34098915 |
Leah Furman1, Stephen Strotmeyer2, Christine Vitale2, Barbara A Gaines2.
Abstract
BACKGROUND: A Mobile Safety Center (MSC) provides safety resources to families to prevent pediatric injury. The primary objective of this study was to assess the impact of an MSC on home safety behaviors.Entities:
Keywords: Injury; Mobile; Pediatric; Prevention; Safety
Year: 2021 PMID: 34098915 PMCID: PMC8184352 DOI: 10.1186/s12889-021-11073-4
Source DB: PubMed Journal: BMC Public Health ISSN: 1471-2458 Impact factor: 3.295
Fig. 1Pictures of the UPMC Children’s Hospital of Pittsburgh’s Mobile Safety Center. (A) Driver’s side exterior. (B) Setup at a community event, including packable kitchen model. (C) Passenger’s side interior, with bathroom model. (D) Rear interior, with living room model and safety item display
Fig. 2Questions and answer choices used to assess participant safety behaviors. Questions are numbered, answer choices are lettered and italicized
Survey results for reported safety behaviors of participants and Friedman testing results comparing reported behaviors across timepoints in the complete follow-up group. All participants, n = 50. Complete follow-up group, n = 26. Friedman testing results reported with chi-squared values (χ2), degrees of freedom (df), and p-values. Significant p-values have been italicized and bolded; p-value < 0.05 was used to determine significance
| Behavior | All participants, pre-test | Complete follow-up group, pre-test | Complete follow-up group, follow-up 1 | Complete follow-up group, follow-up 2 | Friedman results (χ |
|---|---|---|---|---|---|
| Covered every electrical outlet | 46% | 34.6% | 57.7% | 57.7% | χ2(2) = 5.556, |
| Covered at least some electrical outlets | 64% | 65.4% | 80.8% | 88.5% | χ2(2) = 4.222, |
| Made a fire escape plan | 64% | 61.5% | 88.5% | 80.8% | χ2(2) = 7.000, |
| Made a fire escape plan, and shared this with child(ren) | 48% | 53.8% | 57.7% | 73.1% | χ2(2) = 4.000, |
| Installed 2 or more smoke detectors | 86% | 88.5% | 92.3% | 96.2% | χ2(2) = 2.000, |
| Installed 3 or more smoke detectors | 70% | 73.1% | 84.6% | 92.3% | χ2(2) = 5.429, |
| Checked the smoke detector battery within the last month | 32% | 23.1% | 26.9% | 38.5% | χ2(2) = 3.250, |
| Checked the smoke detector battery within the last 3 months | 56% | 53.8% | 50% | 69.2% | χ2(2) = 4.200, |
| Stored sharps in a locked cabinet or drawer | 12% | 3.8% | 7.7% | 11.5% | χ2(2) = 1.500, |
| Stored medicines in a locked cabinet or drawer | 18% | 11.5% | 7.7% | 15.4% | χ2(2) = 2.000, |
| Stored cleaning supplies in a locked cabinet or drawer | 40% | 38.5% | 23.1% | 42.3% | χ2(2) = 4.667, |
| Made National Poison Control Center hotline readily accessible | 38% | 38.5% | 76.9% | 96.2% | χ2(2) = 23.333, |