Literature DB >> 34098476

Development of dipodal fluorescence sensor of iron for real samples based on pyrene modified anthracene.

Süreyya Oğuz Tümay1, Mahsa Haddad Irani-Nezhad2, Alireza Khataee3.   

Abstract

A novel pyrene modified anthracene dipodal sensor was prepared by a simple synthetic method for the sensitive determination of iron ions in real samples. The chemical characterization analyses including nuclear magnetic resonance spectroscopy, Fourier transform infrared spectroscopy, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry were carried out to characterize the target fluorescent sensor. Photophysical and electrochemical behaviors of the sensor were studied by the absorption, excitation-emission matrix analysis, steady-state fluorescence, three-dimensional fluorescence, and cyclic and square wave voltammetry, respectively. The fluorescent sensor properties were evaluated via Ultraviolet-visible and fluorescence spectroscopies. According to obtained results, the fluorescence signal of the sensor was selectively quenched with interaction with Fe3+ ions. The spectrofluorimetric determination of iron, in real water and medicine samples were successfully carried out under optimized experimental conditions. A detection limit and linear working range were calculated as 0.265 μM and 0.275-55.000 μM, respectively which demonstrated the ability of the simple and sensitive sensor for slight amounts of iron. The obtained detection limit for iron determination with the presented novel fluorescent sensor was less than nearly 20 times the tolerance limit (5.40 µM) in drinking water that was determined by the United States Environmental Protection Agency. The accuracy of the newly developed method was evaluated by Inductively coupled plasma optical emission spectroscopy and spike/recovery test which demonstrated that the developed fluorescent sensor has high accuracy for fast, easy and accessible determination of iron at 95% confidence level.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fe(3+) determination; Fluorophore; Medicine; Real water; Turn-off sensor

Year:  2021        PMID: 34098476     DOI: 10.1016/j.saa.2021.120017

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  3 in total

1.  The Impact of a 1,2,3-Triazole Motif on the Photophysical Behavior of Non-K Tetrasubstituted Pyrene with a Substitution Pattern Providing the Long Axial Symmetry.

Authors:  Dawid Zych; Aneta Slodek
Journal:  Molecules       Date:  2022-07-05       Impact factor: 4.927

2.  Electrochromic properties of pyrene conductive polymers modified by chemical polymerization.

Authors:  Rui Li; Haoran Xu; Yuhang Zhang; Lijing Chang; Yang Ma; Yanjun Hou; Shoulei Miao; Cheng Wang
Journal:  RSC Adv       Date:  2021-12-09       Impact factor: 4.036

3.  A reasonably constructed fluorescent chemosensor based on the dicyanoisophorone skeleton for the discriminative sensing of Fe3+ and Hg2+ as well as imaging in HeLa cells and zebrafish.

Authors:  Chuqi Zhang; Xinyan Lv; Xiuhong Liu; Hongyun Chen; Haifeng He
Journal:  RSC Adv       Date:  2022-04-25       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.