Literature DB >> 34097707

Feasibility of deuterium magnetic resonance spectroscopy of 3-O-Methylglucose at 7 Tesla.

Benedikt Hartmann1, Max Müller1, Lisa Seyler1, Tobias Bäuerle1, Tobias Wilferth1, Nikolai Avdievitch2, Loreen Ruhm2, Anke Henning2,3, Alexei Lesiv4, Pavel Ivashkin4, Michael Uder1, Armin M Nagel1,5.   

Abstract

Deuterium Magnetic Resonance Spectroscopy (DMRS) is a non-invasive technique that allows the detection of deuterated compounds in vivo. DMRS has a large potential to analyze uptake, perfusion, washout or metabolism, since deuterium is a stable isotope and therefore does not decay during biologic processing of a deuterium labelled substance. Moreover, DMRS allows the distinction between different deuterated substances. In this work, we performed DMRS of deuterated 3-O-Methylglucose (OMG). OMG is a non-metabolizable glucose analog which is transported similar to D-glucose. DMRS of OMG was performed in phantom and in vivo measurements using a preclinical 7 Tesla MRI system. The chemical shift (3.51 ± 0.1 ppm) and relaxation times were determined. OMG was injected intravenously and spectra were acquired over a period of one hour to monitor the time evolution of the deuterium signal in tumor-bearing rats. The increase and washout of OMG could be observed. Three different exponential functions were compared in terms of how well they describe the OMG washout. A mono-exponential model with offset seems to describe the observed time course best with a time constant of 1910 ± 770 s and an offset of 2.5 ± 1.2 mmol/l (mean ± std, N = 3). Chemical shift imaging could be performed with a voxel size of 7.1 mm x 7.1 mm x 7.9 mm. The feasibility of DMRS with deuterium labelled OMG could be demonstrated. These data might serve as basis for future studies that aim to characterize glucose transport using DMRS.

Entities:  

Year:  2021        PMID: 34097707     DOI: 10.1371/journal.pone.0252935

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  2 in total

1.  Clinical Efficacy of Immunoglobulin Combined with Glucocorticoids in the Treatment of Oculomotor Myasthenia Gravis in Children and the Effect on Serum Immunity.

Authors:  Lijun Fan; Yahui Yang; Fan Zhang; Fei Huang
Journal:  Comput Math Methods Med       Date:  2022-07-08       Impact factor: 2.809

2.  Deuterium metabolic imaging in the human brain at 9.4 Tesla with high spatial and temporal resolution.

Authors:  Loreen Ruhm; Nikolai Avdievich; Theresia Ziegs; Armin M Nagel; Henk M De Feyter; Robin A de Graaf; Anke Henning
Journal:  Neuroimage       Date:  2021-10-09       Impact factor: 6.556

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.