Literature DB >> 34088578

Fluoroscopic versus CT-guided cortical bone trajectory pedicle screw fixation: Comparing trajectory related complications.

Kevin K Kumar1, Bhavya Parikh2, Rashad Jabarkheel3, Benjamin Dirlikov4, Harminder Singh5.   

Abstract

Cortical bone trajectory (CBT) pedicle screw fixation is an emerging technique for treatment of degenerative spine disease which requires either intraoperative fluoroscopy or intraoperative CT guidance (iCT). To date, there has been no direct comparison of these two navigation modalities; here we compare fluoroscopic versus iCT navigation for CBT pedicle screw fixation. We retrospectively reviewed all patients who underwent CBT screw fixation with either fluoroscopic or iCT guidance for lumbar degenerative disease by the senior author. Trajectory-related complications such as medial or lateral breach were compared on postoperative CT, in addition to the incidence of trajectory-related dural tear. We also compared general surgical complications such as postoperative infection and decompression related durotomies. Thirty-eight patients (19 fluoroscopic, 19 CT-guided) who underwent placement of 182 cortical screws (88 fluoroscopic, 94 CT-guided) were identified. In terms of trajectory-related complications, the iCT cohort had fewer medial breaches (1/94) compared to the fluoroscopic cohort (6/88) (p = 0.05). Each group had one lateral breach (p = 0.73). There was one case of CSF leak from screw placement in the fluoroscopic cohort, but none in the iCT cohort (p = 0.48). Overall, there were eight trajectory-related complications in the fluoroscopic cohort versus two in the iCT cohort (p = 0.04). Our data suggests statistically significant decreased trajectory-related complications with iCT-guided CBT screw fixation as compared to fluoroscopically guided. In terms of general surgical complications, while we observed increased postoperative infections in our fluoroscopic cohort, there was no statistically significant difference.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cortical bone trajectory; Cortical screw; Degenerative spine; Fluoroscopy; Image guidance; Navigation

Year:  2021        PMID: 34088578     DOI: 10.1016/j.jocn.2021.05.048

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  1 in total

1.  Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach.

Authors:  Yue Li; Long Chen; Yuzeng Liu; Hongtao Ding; Hongyi Lu; Aixing Pan; Xinuo Zhang; Yong Hai; Li Guan
Journal:  BMC Musculoskelet Disord       Date:  2022-04-06       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.