Literature DB >> 34081339

Reduced esophageal heating in high-power short-duration atrial fibrillation ablation in the contact force catheter era.

Fabricio Vassallo1,2, Lucas Luis Meigre1, Eduardo Serpa1,2, Christiano Lemos Cunha1,2, Hermes Carloni1,2, Aloyr Simoes1,2, Dalton Amaral2, Carlos Lovatto1,2.   

Abstract

BACKGROUND: Atrial fibrillation (AF) ablation is alternative treatment to medical therapy. Most feared complication is atrioesophageal fistula
METHODS: Observational, retrospective analysis of consecutive 355 patients undergoing first AF ablation. Low-power long-duration (LPLD) group contained 158 patients, with 121 (76.58%) having paroxysmal AF who underwent ablation with power 20/30W (anterior and posterior left atrial wall), 17 mL/min flow, and a contact force of 10-30 g for 30 s. High-power short-duration group (HPSD) contained 197 patients, with 113 (57.36%) having paroxysmal AF who underwent ablation at 45/50W of power with a contact force of 8-15 g/10-20 g and a 35 mL/min flow rate for 6-8 s on the anterior and the posterior left atrial wall, respectively. Both groups had pulmonary veins isolated and atrial flutter was ablated when needed. For patients not in sinus rhythm, cardioversion was performed before ablation
RESULTS: There were no complications. LPLD group: Left atrial time 118.74 min, total 145.32 min, radiofrequency time 4317.99s, X-ray 13.42 min, and elevation of luminal esophageal temperature (LET) in 132 (84.53%) patients. HPSD group: Left atrial time 72.16 min, total 93.76 min, radiofrequency time 1511.29s, X-ray 7.6 min, and LET elevation in only 75 (38.07%) patients. A markedly higher rate of first-pass isolation was observed in HPSD compared to LPLD, 77.16% versus 13.29%, respectively. Recurrence occurred in 64 (40.50%) and 32 (16.24%) in 28.45 and 22.35 months in LPLD and HPSD patients, respectively. In LPLD, 10 patients were submitted to endoscopy, and one (10%) had mild erythema and in HPSD, 13 performed the endoscopy, with two (15.38%) patients showing mild erythema
CONCLUSION: HPSD technique compared to the LPLD technique showed significant reduced radiofrequency and fluoroscopy times, higher rate of first-pass isolation, lower recurrence rate, and esophageal temperature elevation and may also have a protective effect avoiding incidental esophageal injury due to these findings.
© 2021 Wiley Periodicals LLC.

Entities:  

Keywords:  catheter ablation; complications; esophageal temperature and high-power short-duration; luminal esophageal monitoring

Mesh:

Year:  2021        PMID: 34081339     DOI: 10.1111/pace.14286

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Comparison of Using Second-Generation Cryoballoon and Radiofrequency Catheter for Atrial Fibrillation Ablation in Patients With the Common Ostium of Inferior Pulmonary Veins.

Authors:  Jia-Hui Li; Hai-Yang Xie; Qi Sun; Xiao-Gang Guo; Yan-Qiao Chen; Zhong-Jing Cao; Jian Ma
Journal:  Front Cardiovasc Med       Date:  2022-01-11

Review 2.  Comparison of Effectiveness and Safety between High-Power Short-Duration Ablation and Conventional Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.

Authors:  Shuyu Jin; Lu Fu; Junrong Jiang; Xingdong Ye; Huiyi Liu; Yanlin Chen; Sijia Pu; Shulin Wu; Yumei Xue
Journal:  J Interv Cardiol       Date:  2022-08-16       Impact factor: 1.776

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.