Literature DB >> 34077904

Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants.

Erica Liverani1, Giulia Rogati2, Stefania Pagani3, Silvia Brogini4, Alessandro Fortunato1, Paolo Caravaggi2.   

Abstract

One of the main biomechanical causes for aseptic failure of orthopaedic implants is the stress shielding. This is caused by an uneven load distribution across the bone normally due to a stiff metal prosthesis component, leading to periprosthetic bone resorption and to implant loosening. To reduce the stress shielding and to improve osseointegration, biocompatible porous structures suitable for orthopaedic applications have been developed. Aim of this study was to propose a novel in-vitro model of the mechanical interaction between metal lattice structures and bovine cortical bone in compression. Analysis of the strain distribution between metal structure and bone provides useful information on the potential stress shielding of orthopaedic implants with the same geometry of the porous scaffold. Full density and lattice structures obtained by the repetition of 1.5 mm edge cubic elements via Laser Powder Bed Fusion of CoCrMo powder were characterized for mechanical properties using standard compressive testing. The two porous geometries were characterized by 750 μm and 1000 μm pores resulting in a nominal porosity of 43.5% and 63.2% respectively. Local deformation and strains of metal samples coupled with fresh bovine cortical bone samples were evaluated via Digital Image Correlation analysis up to failure in compression. Visualization and quantification of the local strain gradient across the metal-bone interface was used to assess differences in mechanical behaviour between structures which could be associated to stress-shielding. Overall stiffness and local mechanical properties of lattice and bone were consistent across samples. Full-density metal samples appeared to rigidly transfer the compression force to the bone which was subjected to large deformations (2.2 ± 0.3% at 15 kN). Larger porosity lattice was associated to lower stiffness and compressive modulus, and to a smoother load transfer to the bone. While tested on a limited sample size, the proposed in-vitro model appears robust and repeatable to assess the local mechanical interaction of metal samples suitable for orthopaedic applications with the bone tissue. CoCrMo scaffolds made of 1000 μm pores cubic cells may allow for a smoother load transfer to the bone when used as constitutive material of orthopaedic implants.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Additive manufacturing; In-vitro model; Lattice structures; Orthopedics; Stress-shielding; Stress/strain measurements

Year:  2021        PMID: 34077904     DOI: 10.1016/j.jmbbm.2021.104608

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  Impact of Femoral Neck Cortical Bone Defect Induced by Core Decompression on Postoperative Stability: A Finite Element Analysis.

Authors:  Daizhu Yuan; Zhanyu Wu; Siwei Luo; Qiang Zou; Zihao Zou; Chuan Ye
Journal:  Biomed Res Int       Date:  2022-05-20       Impact factor: 3.246

2.  A novel hierarchical biofunctionalized 3D-printed porous Ti6Al4V scaffold with enhanced osteoporotic osseointegration through osteoimmunomodulation.

Authors:  Wei Wang; Yinze Xiong; Renliang Zhao; Xiang Li; Weitao Jia
Journal:  J Nanobiotechnology       Date:  2022-02-05       Impact factor: 10.435

3.  Numerical Investigation of the Defects Effect in Additive Manufactured Ti-6Al-4V Struts on Deformation Behavior Based on Microtomographic Images.

Authors:  Michał Doroszko
Journal:  Materials (Basel)       Date:  2022-07-09       Impact factor: 3.748

4.  Finite element analysis of different fixation methods of screws on absorbable plate for rib fractures.

Authors:  Hang Xue; Zhenhe Zhang; Mengfei Liu; Ze Lin; Yori Endo; Guodong Liu; Bobin Mi; Wu Zhou; Guohui Liu
Journal:  Front Bioeng Biotechnol       Date:  2022-07-22

5.  Hybrid Ti6Al4V/Silk Fibroin Composite for Load-Bearing Implants: A Hierarchical Multifunctional Cellular Scaffold.

Authors:  Simone Murchio; Matteo Benedetti; Anastasia Berto; Francesca Agostinacchio; Gianluca Zappini; Devid Maniglio
Journal:  Materials (Basel)       Date:  2022-09-05       Impact factor: 3.748

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.