Literature DB >> 34075313

Innovative electrochemical sensor for the precise determination of the new antiviral COVID-19 treatment Favipiravir in the presence of coadministered drugs.

Mona A Mohamed1,2, Ghada M G Eldin1, Sani M Ismail2, Nadia Zine2, Abdelhamid Elaissari2, Nicole Jaffrezic-Renault2, Abdelhamid Errachid2.   

Abstract

Due the current pandemic of COVID-19, an urgent need is required for serious medical treatments of a huge number of patients. The world health organization (WHO) approved Favipiravir (FAV) as a medication for patients infected with corona virus. In the current study, we report the first simple electrochemical, greatly sensitive sensor using MnO2-rGO nanocomposite for the accurate determination of Favipiravir (FAV). The developed sensor showed a high improvement in the electrochemical oxidation of FAV comparing to the unmodified screen-printed electrode (SPE). The suggested platform constituents and the electrochemical measurements parameters were studied. Under optimal experimental parameters, a current response to the concentration change of FAV was found to be in the linear range of 1.0 × 10-8-5.5 × 10-5 M at pH 7.0 with a limit of detection 0.11 µM and a quantification limit of 0.33 µM. The developed platform was confirmed by the precise analysis of FAV in real samples including dosage form and plasma. The developed platform can be applied in different fields of industry quality control and clinical analysis laboratories for the FAV determination.
© 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  COVID 19; Favipiravir; Graphene derivatives; Real sample analysis

Year:  2021        PMID: 34075313      PMCID: PMC8161794          DOI: 10.1016/j.jelechem.2021.115422

Source DB:  PubMed          Journal:  J Electroanal Chem (Lausanne)        ISSN: 1572-6657            Impact factor:   4.464


Introduction

During the year 2020, the world faced the worst public-health crisis in past hundred years, COVID-19 pandemic. Coronaviruses are large genome viruses of the Nidovirales order, with a positive-strand RNA [1]. European and almost all countries have applied non-pharmaceutical involvements, like school closure and national lockdown that lead to huge economic crises [2]. Regardless of the major efforts to stop its spread, COVID-19 has affected considerable health and financial burden, stressing the urgent need for antiviral treatments [1]. Great efforts have been devoted to the development of an antiviral agent for the halt of the progression of this ailment. During the pandemic influenza in Japan 2014, Favipiravir (FAV) was approved for the treatment of that ailment which showed high potential for the in vitro activity against the acute respiratory syndrome coronavirus-2 [3]. FAV was first applied as a medication against COVID-19 in China-Wuhan, at the red zone of the pandemic origin. After that as the pandemic been in Europe, FAV got approval for emergency use in Italy, and currently has been in use in Japan, Russia, and many other countries around the globe including Egypt [4]. The main advantages of using FAV to treat a new indication, a process called “drug repurposing,” are that FAV is available in high doses and the safety measurements have previously been conducted on a high patients number [5], [6]. Accordingly, the approved medical agent FAV has the potential to be rapidly used on a large scale and be used as a first line of protection to administer to suspect or contact cases during a pathogen lockdown [5]. Based on the above mentioned facts, there is urgent need to develop a sensitive, reliable, fast, low expensive analytical method to trace and determine FAV individuality and in the presence of co-administered drugs. By reviewing the previously published works regarding the determination of FAV, only few methods have been reported for the determination of FAV including HPLC method [7], and spectrofluorometric method [8]. One electrochemical method has been reported for the single determination of FAV [9]. The MnO2 nanomaterials have been used in different applications due to their high capacitance and low cost preparation; they are ecofriendly nanomaterials with an extraordinary stability in alkaline solutions [10]. By the incorporation of carbon with a high electrical conductivity, the conductivity of MnO2 nanomaterials were further enhanced, reduce the equivalent resistance and charge-transfer resistance [10], [11], [12]. Graphene nanostructured materials have received great attention in the past recent years as these materials offer high conductivity, excellent mechanical characteristics, high chemical/thermal stability, with tremendous surface area [13], [14], [15], [16]. So, due to the urgent need to develop a fast, precise and sensitive strategy for the sensitive determination of FAV, we have fabricated the present electrochemical protocol. In this work, hydrothermal one-pot strategy was developed to prepare directly MnO2-rGO nanocomposite using graphene oxide (GO). To the best of our knowledge, there were no literature reporting the use of MnO2-rGO nanocomposite for the modification of screen-printing electrodes (SPE) for the electrochemical determination of FAV.

Experimental

The whole data and description of the used chemicals, apparatus, and methods are described in the electronic supplementary information (ESI) section S2.

Results and Discussion

Characterization of MnO2-rGO nanocomposite

The structural morphology of the prepared MnO2-rGO nanomaterial is displayed in Fig. 1 A. TEM photo is used to examine the structural morphology of MnO2-rGO. TEM displays the structure of graphene with transparent layers and the manganese oxide distribution on its surface, (Fig. 1A). The MnO2-rGO provided high surface area over the common graphite. The bulky particles of the graphite was exfoliated to layers with higher surface area. While the existence of MnO2 nanoparticles with particle’ diameter in the range of 30–85 nm offer much higher surface area that lead to improving the adsorptive affinity towards the FAV throughout the MnO2-rGO/SPE surface. Also, the EDX spectrum was utilized to examine the elemental configuration of the prepared material. Fig. 1B shows the EDX of nanocomposite, indicating the presence of Mn, O, and C.
Fig. 1

A) TEM, B) EDX spectra, C) XRD) D) FE-SEM of MnO2-rGO.

A) TEM, B) EDX spectra, C) XRD) D) FE-SEM of MnO2-rGO. The non-destructive method XRD is a beneficial tool in the description of MnO2. Inset in Fig. 1B shows different peaks at 2θ 18.10°, 29.0°, 31.14°, 37.50°, 44.54°, 50.68°, 59, 98° and 64.70° [11]. The sharp peaks are confirming the stability of MnO2 crystalline nanoparticles. The peaks are correlated to 200, 310, 110, 002, 210, 512, 521 and 541 planes of crystalline MnO2 [17], [18], [19], Fig. 1C. Field Emission Scanning Electron Microscopy (FE-SEM) Fig. 1D displays the hydrothermal synthesized MnO2 nanoparticles of a spherical shape that covered the rGO surface. Fig. S1 depicts the FTIR of graphene oxide and MnO2-rGO nanomaterial. By inspection the FTIR spectra of GO, the CC stretching and C—O—C epoxy stretching peaks appeared at 1642 and 1225 cm−1, while the bands at 1725 and 1054 and 3224–3350 cm−1 correspond to CO stretching, C—O in alkoxy group and OH for the adsorbed H2O. These FTIR indicate the graphite oxidation [20], [21], [22], [23]. While for MnO2-rGO nanocomposite, epoxy, alkoxy and carbonyl peaks were decreased because of the reduction of GO. Moreover, the clear events at 582 and 468 cm−1 are recognized for the MnO2 nanoparticles that completely cover the reduced graphene sheets [24].

Electrochemical characterization of the SPE modified with MnO2-rGO nanocomposite

Next, the electrochemical characteristics of the developed platforms were depicted in 5.0 mM potassium ferricyanide (K3Fe(CN)6) in 0.1 M KCl. MnO2-rGO/SPE (1:1) performance was compared to the bare SPE, and GO/SPE, Fig. 2 A. The redox peaks for MnO2-rGO/SPE were 3.33, and 1.62 times higher than those of SPE, and GO/SPE, respectively, which could be attributed to the increase in the surface area of MnO2-Gr compared to GO. The impedance spectroscopy (EIS) is a potent method for proper specification of the different parameters like mass transport and kinetic as well as the coefficient of charge transfer.
Fig. 2

(A) The recorded CV curves at scan rate (v) of 0.1 V s−1 in 5.0 mM K3Fe(CN)6 (1:1) in 0.1 M KCl solution at SPE, GO/SPE, and MnO2-rGO/SPE electrodes, (B) the electrochemical impedance of each electrode.

(A) The recorded CV curves at scan rate (v) of 0.1 V s−1 in 5.0 mM K3Fe(CN)6 (1:1) in 0.1 M KCl solution at SPE, GO/SPE, and MnO2-rGO/SPE electrodes, (B) the electrochemical impedance of each electrode. Fig. 2B displays the electrochemical impedance spectroscopy (EIS) plot of bare SPE, GO/SPE, and MnO2-Gr/SPE platforms, which were detected in 5.0 mM potassium ferricyanide (K3Fe(CN)6) in 0.1 M KCl. A simple corresponding circuit model was applied to adequate the obtained data. Rs, C and RCT symbolize solution resistance, a capacitance for the double-layer and electron transfer resistance, respectively. ZW is a Warburg -type impedance coupled to RCT, which represents the bulk diffusion. A semicircle with a Warburg-type line was shown in the spectra. The reduction in the semicircle diameter was indicated in the Nyquist plot for the electrochemical platforms GO/SPE and MnO2-rGO/SPE, indicating an enhancement of charge transfer kinetics for those sensors comparing to the unmodified bare SPE. The capacitance (C) was in parallel with the RCT and W impedance. The resistance of charge transfer RCT was valued to be 5970.0 Ω for the unmodified SPE, while it diminished to 4880.0, and 1600.0 Ω for GO/SPE, and MnO2-rGO/SPE, respectively, indicating the significantly lower RCT value at the MnO2-rGO/SPE. The obtained cyclic voltammograms data were in a good agreement with the previous data gained from the electrochemical impedance measurements, showing that MnO2-rGO offers high area along with good electron conduction. The value of resistance of charge transfer RCT can be applied to estimate the rate constant of the electron transfer (k o) through the MnO2-rGO/SPE. Using the following equation [25]: where R is defined as the universal gas constant, T is the thermodynamic temperature (298.15 K), F is the Faraday’s constant (96485 C mol−1), A is the sensor area and C is the electroactive species concentration in the electrolyte medium. Heterogeneous electron transfer rate constant (k o) were estimated and the calculated values were: 1.08 × 10−7, 1.10 × 10−7, and 1.75 × 10−7 cm s−1 for the bare SPE, GO/SPE, and MnO2-rGO/SPE, respectively. By comparing the k constant values, the highest value of k that is related to MnO2-rGO/SPE indicates the effect of MnO2-rGO nanomaterial for the enhancement of electron transfer kinetics throughout the electrode surface.

Electrochemical detection of Favipiravir with the SPE modified with MnO2-rGO nanocomposite

Fig. 3A displays the characteristic SWV of 5.5 × 10−4 M FAV in pH 7.0B.R. buffer at unmodified SPE, GO/SPE, and MnO2-rGO/SPE. Upon adding of 1.0 mM FAV, the unmodified SPE showed an anodic peak current of 14.70 µA at 1.27 V, which related to the oxidation of FAV. As can be seen in Fig. 3A, the value of the current of the electrode rises due to the addition of GO, where the anodic peak appears at 1.25 V with a current value of 18.10 µA. After modification of the sensor with MnO2-rGO, the peak current increased to 25.14 µA at 1.14 V. Consequently, the successful application of MnO2-rGO for the determination of FAV enhanced the analytical signal, due to a higher electron transfer with high electrical conductivity.
Fig. 3

(A) SWV of 5.5 × 10−4 M FAV in B.R. buffer solution pH 7.0 at a SR of 0.1 V s−1 at SPE, GO/SPE, and MnO2-rGO/SPE electrodes, (B) SWV of 5.5 × 10−4 M FAV at different pH values using MnO2-rGO/SPE at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 V. The inset: the plot of IPversus pH.

(A) SWV of 5.5 × 10−4 M FAV in B.R. buffer solution pH 7.0 at a SR of 0.1 V s−1 at SPE, GO/SPE, and MnO2-rGO/SPE electrodes, (B) SWV of 5.5 × 10−4 M FAV at different pH values using MnO2-rGO/SPE at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 V. The inset: the plot of IPversus pH. One of the important factors that affect the electrochemical process is the solution pH. Different pH values were tested using 5.5 × 10−4 M FAV, Fig. 3B. Upon varying the pH from 2.0 to 9.0, the FAV oxidation peak was shifted towards lower potentials values, i.e. more negative values, which might be explained as reduction–deprotonation of FAV [26]. The relation between the peak potential (Ep) and pH values of the buffer solution was linear as: Ep (V) = 1.558 V–0.046 V pH−1, (R2 = 0.9845). The slope value follows Nernst behavior where the included number of electrons and protons are equal during the electrochemical oxidation of FAV. Furthermore, the physiological pH 7.0 was selected as the optimum working one. Chronoamperometric measurements (CA) at 1.23 V for 20 s were performed for the determination of diffusion coefficient (D) applying Cottrell’s law [27], Fig. 4 . The calculated D value was found to be 4.67 × 10−5 cm2 s−1 for FAV at MnO2-rGO/SPE in 0.04 M B.R. buffer (pH 7.0).
Fig. 4

CA measurements for the oxidation of FAV concentrations using MnO2-rGO/SPE in B.R buffer pH 7.0, with a Ps = 500 mV. Inset displays the variant of CA currents at t = 20 s vs. [FAV].

CA measurements for the oxidation of FAV concentrations using MnO2-rGO/SPE in B.R buffer pH 7.0, with a Ps = 500 mV. Inset displays the variant of CA currents at t = 20 s vs. [FAV].

Analytical performance of the SPE modified with MnO2-rGO nanocomposite

For the determination of FAV, SWV experiments were done using MnO2-rGO/SPE in solutions of varying FAV concentrations using pH 7.0B.R. buffer. As depicted in Fig. 5 A, the calibration curve is drawn as peak current Ip vs. FAV concentration. For the range 1.0 × 10−8–5.5 × 10−5 M, the regression equation was I(μA) = 0.048C – 1.10; (R2 = 0.9990). The calculated values for the limit of detection (LOD) and limit of quantification (LOQ) were found to be 9.0 × 10−9 and 2.9 × 10−8 M, respectively.
Fig. 5

A) SWVs measurements at MnO2-rGO/SPE in a pH 7.0B.R. buffer for the concentration range 1.0v10−8–5.5 × 10−5 M FAV at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 V. The inset displays the plot of the Ip and FAV concentration in the concentration range 1.0 × 10−8 to 5.5 × 10−4 M.

A) SWVs measurements at MnO2-rGO/SPE in a pH 7.0B.R. buffer for the concentration range 1.0v10−8–5.5 × 10−5 M FAV at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 V. The inset displays the plot of the Ip and FAV concentration in the concentration range 1.0 × 10−8 to 5.5 × 10−4 M. To check the specificity of MnO2-rGO/SPE, its electro-analytical response was examined for the determination of FAV in the existence of co-administered COVID-19 drugs including fingolimod, remdesivir, and hydroxychloroquine (HCQ). Fingolimod and remdesivir did not show any electrochemical activity using MnO2-rGO/SPE. Paracetamol (PAR) also is prescribed for COVID 19 patients for fever control. Fig. 6 A shows voltammetric response of FAV in presence of PAR as the peak at 0.43 V is corresponding to PAR, while the other at 1.23 V is due to FAV oxidation. These findings are indicating that the simultaneous determination of the co-administered drugs of FAV is practicable using the MnO2-Gr/SPE platform. While for testing hydroxychloroquine (HCQ), two separated peaks appeared at 1.01 and 0.81 V at pH 7. Upon adding 5.5 × 10−4 M FAV, FAV well-separated peak appeared at 1.23 V, Fig. 5B. Comparing to the published electrochemical work [9], our sensor offers wide range of linearity and sensitive determination of FAV alone and the presence of different coadministered drugs were demonstrated for the first time.
Fig. 6

SWVs of A) HCQ, and FAV B) PAR, and FAV at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 using pH 7.0B.R. buffer.

SWVs of A) HCQ, and FAV B) PAR, and FAV at v = 0.1 V s−1, PW = 0.50 V, PH = 0.25 V, SH = 0.02 using pH 7.0B.R. buffer.

Repeatability, reproducibility, and storage stability of the MnO2-rGO/SPE electrochemical sensor

The MnO2-rGO/SPE sensor showed high repeatability and reproducibility for FAV analysis. Five determinations of 1.0 × 10−5 M FAV were performed for a single MnO2-rGO/SPE (intra-day repeatability). The relative standard deviation (RSD) for five determinations of FAV was 1.37%. Furthermore, the series of five different MnO2-rGO/SPE sensors made-up in the same procedure (inter-day reproducibility) have showed the response with an RSD of 1.53% during the electroanalytical determination of 1.0 x10−5 M FAV (Fig. S2). After the preliminary determination of FAV, the MnO2-rGO/SPE sensor was kept in the buffer (pH = 7.0) at 25 °C. The FAV electrochemical response was checked regularly over 4 weeks (Fig. S2). So, four sensors prepared in the same manner were tested in parallel (n = 3). After four weeks, the final current decreased by 12% of the initial current value that proposes the sensor was rationally stable through the checking period. The high stability of the sensor can be gained because of the hydrophobic property of the graphene materials [28], [29], [30], which prevents the formation of a water film on the sensor surface.

Interference studies

Croscarmellose sodium, sodium lauryl sulphate, titanium dioxide, sodium dihydrogen orthophosphate (H6NaO6P), talc, castor oil, mannitol, cellulose, magnesium oxide, and povidone, were examined in order to check any change in the FAV electrochemical signal. Using 1.0 × 10−5 M FAV in a pH 7.0B.R. buffer (0.04 M) solution, each was added, and the magnitude of the anodic peak current was monitored. From the chosen potential interfering substances, none were found to interfere with the electroanalytical sensing of FAV. The tolerance limit was less than ± 5.0% for each interfering substance. Correspondingly, it was found that the use of 40-fold of inorganic ions (e.g. Mg2+, K+, Zn2+, Na+, Fe3+, Ca2+, Cl−, NO3 – and SO4 2−) did not affect the electrochemical responce, as shown in Fig. S3. In addition, the important commonly interfering materials in the biological fluids ascorbic acid (vitamin C, AA) and uric acid (UA) have been tested in the presence of 1.0 × 10−5 M FAV. Also, the precursor of dopamine, levodopa (LEVO) has been checked. The high peak potentials separation between the oxidation peaks of these compounds and FAV indicates the promising determination of FAV in biological fluids without interference, Fig. 7 .
Fig. 7

SWVs using a MnO2-rGO/SPE in a pH 7.0B-R buffer containing 5.0 × 10−5 M FAV, 5.0 × 10−3 M AA, UA and LEVO, respectively, for each at scan rate: 0.1 V s−1, PH = 0.25 V, PW = 0.50 V, SH = 0.02 V.

SWVs using a MnO2-rGO/SPE in a pH 7.0B-R buffer containing 5.0 × 10−5 M FAV, 5.0 × 10−3 M AA, UA and LEVO, respectively, for each at scan rate: 0.1 V s−1, PH = 0.25 V, PW = 0.50 V, SH = 0.02 V.

Analysis of FAV in real samples

The practicability of MnO2-rGO/SPE for the determination of FAV in real samples were tested using SWV technique. The standard addition method was used to evaluate the analytical performance of the sensor for FAV determination. The recovery experiment was presented in Table 1 , which confirm that, the MnO2-rGO/SPE is very sensible for the determination of low and high concentrations of FAV in different real samples.
Table 1

Determination of FAV in human plasma and synthetic tablets using MnO2-rGO/SPE.

SampleAdded (µM)Found (µM)Recovery%
Plasma12.0011.8298.50
55.0054.0398.23
120.00118.9299.10
150.00148.8099.20
Recovery%±R.S.D98.75 ± 0.46
Invisiram® Tablet12.0011.8899.00
55.0054.5099.10
120.00118.5298.77
150.00148.9999.33
Recovery%±R.S.D99.05 ± 0.23
Determination of FAV in human plasma and synthetic tablets using MnO2-rGO/SPE.

Conclusion

In the current study, we have described for the first time, the electrochemical determination of FAV with screen-printed electrode modified with MnO2-rGO nanocomposite. The developed electrochemical platform showed outstanding electrocatalytic activity towards the sensitive determination of FAV with low values of detection and quantification limits along with wide linearity range. Furthermore, FAV was selectively determined using MnO2-rGO/SPE platform in the presence of co-administered drugs with high recovery values. Based on the obtained results for the oxidation of FAV, the quantitative determination of FAV in pharmaceutical preparation and human fluids samples was achieved by a simple, rapid, selective and sensitive SWV technique. Furthermore, along with the excellent characteristics of high accuracy, sensitivity, and reproducibility, the developed sensor offers appropriate simple platform for the sensitive determination of FAV in the clinical work.

CRediT authorship contribution statement

Mona A. Mohamed: Investigation. Ghada M. G. Eldin: Investigation. Sani M. Ismail: Investigation. Nadia Zine: Writing - original draft preparation. Abdelhamid Elaissari: Conceptualization. Nicole Jaffrezic-Renault: Writing - review and editing. Abdelhamid Errachid: Funding acquisition, Writing - review and editing.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
  14 in total

1.  Application of electrochemically reduced graphene oxide on screen-printed ion-selective electrode.

Authors:  Jianfeng Ping; Yixian Wang; Yibin Ying; Jian Wu
Journal:  Anal Chem       Date:  2012-03-12       Impact factor: 6.986

2.  Novel MWCNTs/graphene oxide/pyrogallol composite with enhanced sensitivity for biosensing applications.

Authors:  Mona A Mohamed; Ali M Yehia; Craig E Banks; Nageh K Allam
Journal:  Biosens Bioelectron       Date:  2016-10-11       Impact factor: 10.618

3.  3D spongy graphene-modified screen-printed sensors for the voltammetric determination of the narcotic drug codeine.

Authors:  Mona A Mohamed; Dalia M El-Gendy; Nashaat Ahmed; Craig E Banks; Nageh K Allam
Journal:  Biosens Bioelectron       Date:  2017-10-11       Impact factor: 10.618

Review 4.  Drug repurposing: progress, challenges and recommendations.

Authors:  Sudeep Pushpakom; Francesco Iorio; Patrick A Eyers; K Jane Escott; Shirley Hopper; Andrew Wells; Andrew Doig; Tim Guilliams; Joanna Latimer; Christine McNamee; Alan Norris; Philippe Sanseau; David Cavalla; Munir Pirmohamed
Journal:  Nat Rev Drug Discov       Date:  2018-10-12       Impact factor: 84.694

5.  MnO2 prepared by hydrothermal method and electrochemical performance as anode for lithium-ion battery.

Authors:  Lili Feng; Zhewen Xuan; Hongbo Zhao; Yang Bai; Junming Guo; Chang-Wei Su; Xiaokai Chen
Journal:  Nanoscale Res Lett       Date:  2014-06-10       Impact factor: 4.703

6.  Rapid incorporation of Favipiravir by the fast and permissive viral RNA polymerase complex results in SARS-CoV-2 lethal mutagenesis.

Authors:  Ashleigh Shannon; Barbara Selisko; Nhung-Thi-Tuyet Le; Johanna Huchting; Franck Touret; Géraldine Piorkowski; Véronique Fattorini; François Ferron; Etienne Decroly; Chris Meier; Bruno Coutard; Olve Peersen; Bruno Canard
Journal:  Nat Commun       Date:  2020-09-17       Impact factor: 14.919

7.  Experimental design approach for development of spectrofluorimetric method for determination of favipiravir; a potential therapeutic agent against COVID-19 virus: Application to spiked human plasma.

Authors:  Safa M Megahed; Ahmed A Habib; Sherin F Hammad; Amira H Kamal
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2020-11-28       Impact factor: 4.098

Review 8.  Role of favipiravir in the treatment of COVID-19.

Authors:  Shashank Joshi; Jalil Parkar; Abdul Ansari; Agam Vora; Deepak Talwar; Mangesh Tiwaskar; Saiprasad Patil; Hanmant Barkate
Journal:  Int J Infect Dis       Date:  2020-10-30       Impact factor: 3.623

9.  Comparison of HPLC and UV Spectrophotometric Methods for Quantification of Favipiravir in Pharmaceutical Formulations.

Authors:  İbrahim Bulduk
Journal:  Iran J Pharm Res       Date:  2021       Impact factor: 1.696

View more
  8 in total

1.  Core shell stationary phase for a novel separation of some COVID-19 used drugs by UPLC-MS/MS Method: Study of grapefruit consumption impact on their pharmacokinetics in rats.

Authors:  Sally Tarek Mahmoud; Marwa A Moffid; Rawda M Sayed; Eman A Mostafa
Journal:  Microchem J       Date:  2022-07-15       Impact factor: 5.304

2.  Rapid and ecofriendly UPLC quantification of Remdesivir, Favipiravir and Dexamethasone for accurate therapeutic drug monitoring in Covid-19 Patient's plasma.

Authors:  Aml A Emam; Eglal A Abdelaleem; Esraa H Abdelmomen; Refaat H Abdelmoety; Rehab M Abdelfatah
Journal:  Microchem J       Date:  2022-05-13       Impact factor: 5.304

3.  Voltammetric sensor based on bimetallic nanocomposite for determination of favipiravir as an antiviral drug.

Authors:  Mohammad Mehmandoust; Yasamin Khoshnavaz; Mustafa Tuzen; Nevin Erk
Journal:  Mikrochim Acta       Date:  2021-11-27       Impact factor: 5.833

4.  Core-shell nanocomposite of flower-like molybdenum disulfide nanospheres and molecularly imprinted polymers for electrochemical detection of anti COVID-19 drug favipiravir in biological samples.

Authors:  Shuang Wang; Chen Wang; Yuxiao Xin; Qiuyun Li; Weilu Liu
Journal:  Mikrochim Acta       Date:  2022-03-01       Impact factor: 6.408

5.  Favipiravir (SARS-CoV-2) degradation impurities: Identification and route of degradation mechanism in the finished solid dosage form using LC/LC-MS method.

Authors:  Divya Kumar Vemuri; Rambabu Gundla; Naresh Konduru; Ravindra Mallavarapu; Naresh Kumar Katari
Journal:  Biomed Chromatogr       Date:  2022-04-06       Impact factor: 1.911

6.  Quantitative analysis of favipiravir and hydroxychloroquine as FDA-approved drugs for treatment of COVID-19 using synchronous spectrofluorimetry: application to pharmaceutical formulations and biological fluids.

Authors:  Mona E El Sharkasy; Manar M Tolba; Fathalla Belal; Mohamed Walash; Rasha Aboshabana
Journal:  Luminescence       Date:  2022-04-10       Impact factor: 2.613

Review 7.  The role of electrochemical biosensors in SARS-CoV-2 detection: a bibliometrics-based analysis and review.

Authors:  Shudan Mao; Li Fu; Chengliang Yin; Xiaozhu Liu; Hassan Karimi-Maleh
Journal:  RSC Adv       Date:  2022-08-12       Impact factor: 4.036

8.  Novel environment friendly TLC-densitometric method for the determination of anti-coronavirus drugs "Remdesivir and Favipiravir": Green assessment with application to pharmaceutical formulations and human plasma.

Authors:  Deena A M Noureldeen; John M Boushra; Adel S Lashien; Ahmed F Abdel Hakiem; Tamer Z Attia
Journal:  Microchem J       Date:  2021-12-18       Impact factor: 4.821

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.