Literature DB >> 34074423

High throughput determination of free biogenic monoamines and their metabolites in urine using thin-film solid phase microextraction.

Liqin Chen1, Varoon Singh1, Daniel Rickert1, Abir Khaled1, Janusz Pawliszyn2.   

Abstract

UPLC-MS/MS methods are the gold standard for routine, high-throughput measurements of biogenic monoamines for the diagnosis of catecholamine-producing tumors. However, this cannot be achieved without employing efficient sample pretreatment methods. Therefore, two pretreatment methods, thin-film solid phase microextraction (TF-SPME) and packed fibers solid phase extraction (PFSPE), were developed and evaluated for the analysis of biogenic monoamines and their metabolites in urine. A hydrophilic-lipophilic balance (HLB) coating was chosen for the thin-film blade format SPME method and compared with a Polycrown ether (PCE) composite nanofiber used as an adsorbent for the PFSPE method. Under optimal conditions, the absolute extraction recovery and relative matrix effect of the newly developed TF-SPME method were determined to be 35.7-74.8% and 0.47-3.63%, respectively. The linearity was 0.25-500 ng mL-1 for norepinephrine, epinephrine, dopamine, normetanephrine 3-methoxytyramine, serotonin, histamine, and 0.1-500 ng mL-1 for metanephrine. The intra-and inter-assay coefficients of variation were 0.7-8.7%, and the respective accuracies were calculated to be 90.8-104.7% and 89.5-104.5% for TF-SPME. Compared with the PFSPE method, the TF-SPME method had a higher extraction efficiency, lower matrix effects and a wider linear range for eight target substances, which ensured higher accuracy of simultaneous detection of all compounds of interest. Therefore, the proposed TF-SPME method can be employed for the high throughput screening for neuroendocrine tumors in a routine clinical setting and other relative research by simultaneous quantitation of urine eight biological monoamines in a single run.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biogenic monoamines; Hydrophilic-lipophilic balanced polymeric particles; Liquid chromatography-tandem mass spectrometry; Solid phase microextraction; Urine

Mesh:

Substances:

Year:  2021        PMID: 34074423     DOI: 10.1016/j.talanta.2021.122438

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Current Sample Preparation Methodologies for Determination of Catecholamines and Their Metabolites.

Authors:  Nian Shi; Xinmiao Bu; Manyu Zhang; Bin Wang; Xinli Xu; Xuezhong Shi; Dilshad Hussain; Xia Xu; Di Chen
Journal:  Molecules       Date:  2022-04-22       Impact factor: 4.927

2.  [Determination of three urinary catecholamines and serotonin by on-line packed-fiber solid-phase extraction].

Authors:  Yueling Bi; Tong Xu; Liqin Chen
Journal:  Se Pu       Date:  2021-12
  2 in total