24 GHz Flexible Antenna for Doppler Radar-Based Human Vital Signs Monitoring.

Nitin Kathuria1, Boon-Chong Seet1.   

Abstract

Noncontact monitoring of human vital signs has been an emerging research topic in recent years. A key approach to this monitoring is the use of the Doppler radar concept which enables real-time vital signs detection, resulting in a new class of radar system known as bio-radar. The antennas are a key component of any bio-radar module and their designs should meet the common requirements of bio-radar applications such as high radiation directivity and mechanical flexibility. This paper presents the design of a four-element antenna array on a flexible liquid crystal polymer (LCP) substrate of 100 μm thickness and εr of 3.35. The designed antenna array can be used with a 24 GHz bio-radar for vital signs monitoring in a non-contact manner. It features a relatively compact size of 36.5 × 53 mm2 and measured gain of 5.81 dBi. The two vital signs: breathing rate (BR) and heart rate (HR) of two human subjects are detected with relatively good accuracy using the fabricated antenna array and radio frequency (RF) output power of -3 dBm from a distance of approximately 60 cm. The effect of bending on the antenna performance is also analyzed.

Entities:  

Keywords:  Doppler radar; bending analysis; bio-radar; flexible antenna; human vital signs; liquid crystal polymer; noncontact monitoring

Mesh:

Year:  2021        PMID: 34072148     DOI: 10.3390/s21113737

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  2 in total

1.  Reconstruction of out-of-plane cardiac displacement patterns as observed on the chest wall during various phases of ECG by capacitance transducer.

Authors:  G Ramachandran; S Swarnamani; M Singh
Journal:  IEEE Trans Biomed Eng       Date:  1991-04       Impact factor: 4.538

2.  An Effective Design of Wearable Antenna with Double Flexible Substrates and Defected Ground Structure for Healthcare Monitoring System.

Authors:  Ameena Banu Mustafa; Tamilselvi Rajendran
Journal:  J Med Syst       Date:  2019-05-17       Impact factor: 4.460

  2 in total
  2 in total

1.  Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas.

Authors:  Mona K El Abbasi; Mervat Madi; Herbert F Jelinek; Karim Y Kabalan
Journal:  Sensors (Basel)       Date:  2022-05-25       Impact factor: 3.847

Review 2.  Non-Invasive Data Acquisition and IoT Solution for Human Vital Signs Monitoring: Applications, Limitations and Future Prospects.

Authors:  Mahmoud Salem; Ahmed Elkaseer; Islam A M El-Maddah; Khaled Y Youssef; Steffen G Scholz; Hoda K Mohamed
Journal:  Sensors (Basel)       Date:  2022-09-01       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.