Sadegh Salmanpour1, Toktam Tavana2, Ali Pahlavan3, Mohammad A Khalilzadeh4, Ali A Ensafi5, Hassan Karimi-Maleh6, Hadi Beitollahi7, Elaheh Kowsari8, Daryoush Zareyee2.
Abstract
A novel multiwall carbon nanotubes (MWCNTs) modified carbon ionic liquid electrode (CILE) was fabricated and used to investigate the electrochemical behavior of norepinephrine (NP). MWCNTs/CILE was prepared by mixing hydrophilic ionic liquid, 1-methyl-3-butylimidazolium bromide (MBIDZBr), with graphite powder, MWCNTs, and liquid paraffin. The fabricated MWCNTs/CILE showed great electrocatalytic ability to the oxidation of NE. The electron transfer coefficient, diffusion coefficient, and charge transfer resistant (Rct) of NE at the modified electrode were calculated. Differential pulse voltammetry of NE at the modified electrode exhibited two linear dynamic ranges with slopes of 0.0841 and 0.0231μA/μM in the concentration ranges of 0.3 to 30.0μM and 30.0 to 450.0μM, respectively. The detection limit (3σ) of 0.09μM NP was achieved. This modified electrode exhibited a good ability for well separated oxidation peaks of NE and acetaminophen (AC) in a buffer solution, pH 7.0. The proposed sensor was successfully applied for the determination of NE in human urine, pharmaceutical, and serum samples.Entities:
Keywords: Acetaminophen; Ionic liquid; Multiwall carbon nanotubes; Norepinephrine; Voltammetry
Year: 2012 PMID: 34062675 DOI: 10.1016/j.msec.2012.05.038
Source DB: PubMed Journal: Mater Sci Eng C Mater Biol Appl ISSN: 0928-4931 Impact factor: 7.328