| Literature DB >> 34059376 |
Linda Chami1, Alain Giron2, Malek Ezziane3, Véronique Leblond4, Frédéric Charlotte5, Claire Pellot-Barakat6, Olivier Lucidarme1.
Abstract
The diagnostic contribution of 2-D shear-wave elastography (SWE) in management of superficial lymph nodes (LNs) of any origin was evaluated in 222 patients referred for needle core biopsy. Each patient underwent conventional B-mode/Doppler ultrasound examinations (conventional ultrasound) and SWE. Quantitative SWE parameters and qualitative SWE map features were extracted. Carcinomas were found to be significantly stiffer than benign LNs (29.5 ± 32.3 kPa vs. 6.7 ± 12.3 kPa). Lymphomas exhibited intermediate stiffness (11.4 ± 5.2 kPa). Qualitative SWE analysis provided color patterns specific to histopathology (stiff rim, nodular and undetermined patterns related to malignancy and blue pattern to benignity). Adding SWE to conventional ultrasound improved the sensitivity of LN diagnosis (from 81.1% to 92.0%) but decreased its specificity (from 73.2% to 67.6%) because of the high prevalence of lymphomas compared with carcinomas. Inter-observer agreement for quantitative SWE was good (intra-class correlation coefficient = 0.82) as was inter-observer diagnostic agreement for qualitative SWE (κ = 0.65). LN location and histology type were found to influence the reported diagnostic performance of SWE.Entities:
Keywords: Diagnostic ultrasound; Lymph nodes; Lymphomas; Performance analysis; Shear wave elastography
Year: 2021 PMID: 34059376 DOI: 10.1016/j.ultrasmedbio.2021.04.008
Source DB: PubMed Journal: Ultrasound Med Biol ISSN: 0301-5629 Impact factor: 2.998