| Literature DB >> 34046248 |
Amy Hellman1, John M Bertoni1, Danish E Bhatti1, Najib Murr2, Diego Torres-Russotto1.
Abstract
Background: Orthostatic tremor (OT) is characterized by a sensation of instability while standing, associated with high frequency (1318 Hz) tremor in the legs. Small retrospective series have reported electroencephalography (EEG) findings in OT with discordant results.Entities:
Keywords: EEG; Movement Disorders; OT Pathophysiology; Orthostatic tremor; Tremor
Mesh:
Year: 2021 PMID: 34046248 PMCID: PMC8139292 DOI: 10.5334/tohm.596
Source DB: PubMed Journal: Tremor Other Hyperkinet Mov (N Y) ISSN: 2160-8288
EEG Results.
| SUBJECT | EEG RESULTS | ARTIFACT | TREMOR FREQUENCY ON EMG |
|---|---|---|---|
| 1 | Normal | 15 Hz in posterior electrodes on EEG | 15 Hz |
| 2 | Normal | 15 Hz in occipital electrodes on EEG | No EMG |
| 3 | Normal | 17.6 Hz in EKG | No EMG |
| 4 | Normal | 17 Hz in inferior orbital electrode on EEG, also seen in frontal, occipital and temporal electrodes | No EMG |
| 5 | Generalized fast activity of low voltage which could be consistent with generalized medications effect | 15.6 Hz in infraorbital electrode on EEG | 15.6 Hz |
| 6 | Normal | Present in bilateral temporal regions on EEG but not able to be measured | 15.5 Hz |
| 7 | Normal | Present in temporal regions on EEG but frequency did not match (exact frequency not reported) | 18 Hz |
| 8 | Normal | None noted | Could not be measured |
| 9 | Normal | 16.5 Hz in T3 and T5 electrodes on EEG and EKG | No EMG |
| 10 | Normal | Present in occipital regions on EEG | 17 Hz |
| 11 | Normal | 15 Hz in Oz electrode on EEG | No EMG |
| 12 | Normal | 13.2 Hz in Oz electrode on EEG | 13.2 Hz |
| 13 | Normal | 15 Hz in T5 and T3 electrodes on EEG while sitting and other midline and central electrodes when standing | No EMG |
| 14 | Left anterior mid-temporal slow activity | Could not be measured | No EMG |
| 15 | Right anterior mid-temporal slow activity | 18 Hz in occipital electrodes on EEG | No EMG |
| 16 | Normal | 14 Hz in occipital electrodes on EEG | No EMG |
| 17 | Normal | Present in occipital electrodes but not able to be measured | 15.5 Hz |
| 18 | Normal | Could not be measured | Could not be measured |
| 19 | Normal | 16 Hz in Oz electrode on EEG | No EMG |
| 20 | Normal | None | 15.5 Hz |
| 21 | Normal | 14.5 Hz in posterior electrodes on EEG | 14.5 Hz |
| 22 | Normal | 16.5 Hz in Oz and O2 electrodes on EEG | 16.5 Hz |
| 23 | Normal | 14 Hz in infraorbital electrode on EEG | No EMG |
| 24 | Normal | 18.5 Hz in EKG | No EMG |
| 25 | Normal | 15.516 Hz in Oz, O1, O2, T5, and T6 electrodes on EEG | No EMG |
| 26 | Normal | Present in bilateral temporal, midline, and posterior head leads on EEG but could not be measured | Could not be measured |
| 27 | Normal | 15.5 Hz in occipital electrodes on EEG | Could not be measured |
| 28 | Normal | 16 Hz in O1, O2, Oz, and T4 electrodes on EEG | 16 Hz |
| 29 | Right anterior mid-temporal slow activity | 7.3 Hz in O1 and Oz electrodes on EEG | 7.3 Hz |
| 30 | Normal | Present in EEG but could not be measured | 15.5 Hz |