Literature DB >> 34045498

A correlation study of beat-to-beat R-R intervals and pulse arrival time under natural state and cold stimulation.

Rong-Chao Peng1, Yi Li2, Wen-Rong Yan3,4,5.   

Abstract

Beat-to-beat R-R intervals (RRI) and pulse arrival time (PAT) provide pivotal information to evaluate cardiac autonomic functions for predicting arrhythmias and cardiovascular morbidity. However, their relationship has not been clearly understood. In this study, we simultaneously recorded electrocardiograms and photoplethysmograms on 34 subjects in the natural state, and on 55 subjects under the cold stimulation. The RRI and the PAT were calculated and then analyzed using Pearson correlation coefficient. The results showed that the RRI and the PAT were strongly correlated (r = 0.562) and the RRI series were 2.18 ± 0.40 beats advanced to the PAT series. After smoothing, the RRI and the PAT were more correlated in the low frequency than in the high frequency. Furthermore, when involving RRI with the phase effect, the proposed PAT based model showed better performance for blood pressure estimation. We think these results are helpful to understand the underlying regulatory mechanisms of the two cardiovascular factors, and would provide useful suggestions for non-invasive cuffless blood pressure estimation.

Entities:  

Year:  2021        PMID: 34045498     DOI: 10.1038/s41598-021-90056-2

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  8 in total

1.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration.

Authors:  W Chen; T Kobayashi; S Ichikawa; Y Takeuchi; T Togawa
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

2.  The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time technique.

Authors:  Mico Yee Man Wong; Emma Pickwell-MacPherson; Yuan Ting Zhang; Jack C Y Cheng
Journal:  Eur J Appl Physiol       Date:  2010-09-08       Impact factor: 3.078

3.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure.

Authors:  R A Payne; C N Symeonides; D J Webb; S R J Maxwell
Journal:  J Appl Physiol (1985)       Date:  2005-09-01

4.  A cardiocardiac sympathovagal reflex in the cat.

Authors:  P J Schwartz; M Pagani; F Lombardi; A Malliani; A M Brown
Journal:  Circ Res       Date:  1973-02       Impact factor: 17.367

5.  A real-time QRS detection algorithm.

Authors:  J Pan; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

6.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

7.  Threshold-based fall detection using a hybrid of tri-axial accelerometer and gyroscope.

Authors:  Fu-Tai Wang; Hsiao-Lung Chan; Ming-Hung Hsu; Cheng-Kuan Lin; Pei-Kuang Chao; Ya-Ju Chang
Journal:  Physiol Meas       Date:  2018-10-11       Impact factor: 2.833

8.  Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor.

Authors:  Josep Solà; Martin Proença; Damien Ferrario; Jacques-André Porchet; Abdessamad Falhi; Olivier Grossenbacher; Yves Allemann; Stefano F Rimoldi; Claudio Sartori
Journal:  IEEE Trans Biomed Eng       Date:  2013-07-10       Impact factor: 4.538

  8 in total
  1 in total

1.  A fusion approach to improve accuracy and estimate uncertainty in cuffless blood pressure monitoring.

Authors:  Cederick Landry; Sean D Peterson; Arash Arami
Journal:  Sci Rep       Date:  2022-05-13       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.