Hemodialysis-Related Glycemic Disarray Proven by Continuous Glucose Monitoring; Glycemic Markers and Hypoglycemia.

Akinori Hayashi1,2, Naoya Shimizu2, Agena Suzuki2, Kenta Matoba2, Akari Momozono2, Tsuguto Masaki2, Akifumi Ogawa2, Ibuki Moriguchi3, Koji Takano2, Naoyuki Kobayashi3, Masayoshi Shichiri2.   

Abstract

OBJECTIVE: There is a high risk of asymptomatic hypoglycemia associated with hemodialysis (HD) using glucose-free dialysate; therefore, the inclusion of glucose in the dialysate is believed to prevent intradialytic hypoglycemia. However, the exact glycemic fluctuation profiles and frequency of asymptomatic hypoglycemia using dialysates containing >100 mg/dL glucose have not been determined. RESEARCH DESIGN AND METHODS: We evaluated the glycemic profiles of 98 patients, 68 of whom were men, with type 2 diabetes undergoing HD (HbA1c 6.4 ± 1.2%; glycated albumin 20.8 ± 6.8%) with a dialysate containing 100, 125, or 150 mg/dL glucose using continuous glucose monitoring.
RESULTS: Sensor glucose level (SGL) showed a sustained decrease during HD, irrespective of the dialysate glucose concentration, and reached a nadir that was lower than the dialysate glucose concentration in 49 participants (50%). Twenty-one participants (21%) presented with HD-related hypoglycemia, defined by an SGL <70 mg/dL during HD and/or between the end of HD and their next meal. All these hypoglycemic episodes were asymptomatic. Measures of glycemic variability calculated using the SGL data (SD, coefficient of variation, and range of SGL) were higher and time below range (<70 mg/dL) was lower in participants who experienced HD-related hypoglycemia than in those who did not, whereas time in range between 70 and 180 mg/dL, time above range (>180 mg/dL), HbA1c, and glycated albumin of the two groups were similar.
CONCLUSIONS: Despite the use of dialysate containing 100-150 mg/dL glucose, patients with diabetes undergoing HD experienced HD-related hypoglycemia unawareness frequently. SGL may fall well below the dialysate glucose concentration toward the end of HD.
© 2021 by the American Diabetes Association.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34045240     DOI: 10.2337/dc21-0269

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  1 in total

Review 1.  Use of Continuous Glucose Monitoring in the Assessment and Management of Patients With Diabetes and Chronic Kidney Disease.

Authors:  James Ling; Jack K C Ng; Juliana C N Chan; Elaine Chow
Journal:  Front Endocrinol (Lausanne)       Date:  2022-04-22       Impact factor: 6.055